Warnings: This device is required to be connected to a building electrical circuit with over
current protection corresponding to the input current on the equipment label.
Com
HLC-0
+12V
Clr
Take
The term "grounding" refers to a separate wire, usually with green insulation, which is
connected from the equipment case to earth ground. This is not the same as the neutral or
common and must not be confused with them. The neutral is a separate, load-carrying
conductor, and common refers to the control signal's common or reference voltage which
should only be allowed to reach ground at a single point in the entire system (typically at the
control console) to avoid ground loops.
The pack will dim any load up to 1200W per channel on the DM412 or up to 2400W per
channel on the DM124. The load may be incandescent, inductive or resistive. This includes
conventional incandescent, quartz incandescent, "rain lights", pin-beams, and similar "low-
voltage" lighting loads containing transformers. Fluorescent and neon loads can be controlled
by the Shoebox with no damage to the dimmer, but the nature of these loads requires
specialized circuitry to get full range dimming. Consult the factory if you need to dim such
loads.
WALL MOUNT SHOEBOX - USER MANUAL
Com
HLC-4
+12V
Clr
Out1
Out2
Out3
Out4
Clr
Take
+12V
Example Wiring Diagram of DM412-WM, HLC-4, and HLC-0

Grounding

Load Connections

from DMX
console
DMX Data
+15
C - + - +
G
1 2 3 4 5
L
N
DM412
4
3
2
1
4 3 2 1 Com
power
from
breaker
6