- ページ 4

ケーブルとコネクター Amphenol AMPHE-EX L-2124のPDF 組立説明書をオンラインで閲覧またはダウンロードできます。Amphenol AMPHE-EX L-2124 17 ページ。

The following instructions apply to equipment covered by Amphenol ATEX and IECEx
The equipment may be used with flammable gases and vapours with apparatus group(s) IIA, IIB, & IIC and with
temperature classes T6, T5, T4, T3, T2 & T1.
The equipment is only certified for use in ambient temperatures in the range -40°C to +40
used outside this range.
Hermetic version can be used in ambient temperatures in the range -40°C to +85°C.
The product complies with the following standards:
EN 60079-0:
(IEC 60079-0)
EN 60079-1:
(IEC 60079-1)
EN 60079-7:
(IEC 60079-7)
EN 60079-28:
(IEC60079-28)
EN 60079-31:
(IEC60079-28)
Installation shall be carried out by suitably-trained personnel in accordance with the applicable code of practice e.g. EN/IEC
60079-14 or EN/IEC 61241-14. It is the end user's responsibility to ensure that the product, as specified and confirmed by
the product label, is suitable for it intended application.
Inspection and maintenance of this equipment shall be carried out by suitably trained personnel in accordance with the
applicable code of practice e.g. EN/IEC 60079-17 or EN/IEC 61241-17.
Repair of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice
e.g. EN/IEC 60079-19.
Components to be incorporated into or used as replacement parts of the equipment shall be fitted by suitably trained
personnel, using only components purchased from Amphenol or an Amphenol approved distributor. Any use of non-
approved components/suppliers will invalidate the certification for that product.
The certification of this equipment relies upon the following materials used in its construction:
1) Connector Materials:
a. (Standard Base Material) ASTM B211 or B221 Alloy 6061-T6, Aluminum (<7%Mg),
b. (Optional Base Material) ASTM 5640, Alloy 303, Stainless Steel
certificates.
Explosive atmospheres – Part 0: Equipment-General requirements
Explosive atmospheres - Part 1: Equipment protection by Flameproof enclosures "d"
Explosive atmospheres –Part 7: Equipment protection by increased safety "e"
Protection of equipment and transmission systems using optical radiation
Equipment dust ignition protection by enclosure "t"
Page 4 of 17
o
C and should not be