- ページ 6

キャッシュカウンター Baumer NE215のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer NE215 40 ページ。 Electronic preselection counter

Baumer NE215 取扱説明書
Counter connect
22 21 20 19 18 17 16 15 14 13 12
+24V 0V
11
10
9
8
7
6
5
B1
P2
P1
Output
max. 250 V
Terminal - Terminal
* Models with scaling
26 25 24 23
22
RS232
RS485
6
3
Counter connect
This chapter will explain how the contacts are assigned.
Under chapters 3.1 to 3.5 you will find actual tips and technical data
for the various connections.
The electrical inputs and outputs are assigned to two 12-pole plug-in
screw terminals, coded to prevent reversed polarity.
Assignment
Contact
1
2
3
B
A
4
Count
5
6
4
3
2
1
7
8
9
- Terminal
10
11
12
13
14
15
21
16
17
18
19
20
21
22
23
24
25
26
Litz contact only by means of connector sleeves with insulating
enclosures for reasons of shock protection according to VDE 0411
part 100. Do not otherwise assign contacts that have been left
unassigned ex factory. We recommend to screen all encoder
terminal leads and to ground the shield on one side. Shields on
both sides are recommended in case of RF interference or in case
of equipotential bonding over long distances. The encoder leads
should not be in the same phase winding as the MAINS supply and
the output contact leads.
Function
Not assigned
Supply voltage
Supply voltage
1 Relay contact output P1
1 Relay contact output P2
1 Relay contact output B1
Signal input, track A
Signal input, track B
Reset XP
Time meter
Signal input, track B1
Reset B1
Coding input for input logic
Encoder supply 0 Volt
Encoder supply +24 Volt
Option RS485 T,R-
Option RS485 T,R+
Option RS232 TXD
-
Option RS232 RXD
Option RS232 GND
NE215