- ページ 5

アクセサリー Amphenol Temposonics GPのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Amphenol Temposonics GP 8 ページ。 Linear position sensor analog and digital pulse outputs
Amphenol Temposonics GP にも: 簡単な指導 (12 ページ)

Programming & Diagnostics Using a PDA - G-Series Digital Pulse Output Sensors Only.
Using the G-Series infrared (IR) interface, users can program G-Series
digital-pulse sensors using a Personal Digital Assistant (PDA). The PDA
interface can also be used as a monitor for position feedback as well as
diagnostics.
R R e e q q u u i i r r e e d d E E q q u u i i p p m m e e n n t t : :
• G-Series model sensor
• Mating cable for sensor (if necessary)
• Palm
OS based PDA and G-Series PDA configuration software
TM
installed (see below)
• Sensor power supply (+20.4 to +28.8 Vdc for input voltage option 1, and
+9 to +23 Vdc for option 2)
The required software file for G-Series PDA programming is named
MTS_GSeries.prc.
Establishing PDA Communications
Caution:
Prior to initiating G-Series programming, it is critical that the user ensures that taking the sensor out of normal operating mode or
modifying the sensor's operating parameters will not cause harm to the process utilizing the G-Series sensor feedback, nor to any persons
associated.
Use of the G-Series IR programming tools requires a clear path from the
programming device to the sensor LEDs. Depending on the PDA device
used, IR communication with the sensor may be limited to 3 inches (75 mm)
from the LED window.
1. Turn the PDA on, (power should not yet be applied to the sensor).
Select MTS G-Series from the main PDA menu.
2. Align the IR window of the PDA device with the LED window of the
sensor as shown in Figure 3 below. Select Begin Prog then
immediately apply power to the sensor. The LED on the sensor will
flash red only when IR communications is established within the 5
seconds of applying power to the sensor (see Figure 3 below).
Figure 3 - Establishing PDA Communications
IR signal
Software can be found on "G-Series Documentation and Software" CD ROM
(part no. 550971) or downloaded from
http://www.products.mtslinearsensors.com. T T h h i i s s s s o o f f t t w w a a r r e e i i s s c c o o m m p p a a t t i i b b l l e e
w w i i t t h h P P a a l l m m O O S S v v e e r r s s i i o o n n 3 3 . . 3 3 a a n n d d a a b b o o v v e e , , w w i i t t h h t t h h e e s s e e P P a a l l m m m m o o d d e e l l s s o o n n l l y y : : P P a a l l m m
I I I I I I , , I I I I I I c c , , V V , , m m 1 1 0 0 0 0 , , m m 1 1 3 3 0 0 , , a a n n d d Z Z i i r r e e . . To load the software to your PDA, select
the program for installation and synchronize the PDA with your PC.
H H a a r r d d w w a a r r e e S S e e t t u u p p N N o o t t e e s s : :
1. Make sure sensor is NOT connected to the control or sensor interface.
2. Do not apply power to the sensor yet. However, make sure that the
appropriate power source and ground connections are correct as
indicated in Tables 2 or 3 on page 2.
3. If IR communication is not established before the timeout period, simply
power the sensor down and begin step 2 again.
Note:
Once the PDA IR "Begin Program" input is received, the sensor will enter
and remain in program mode until this mode is exited or the sensor power
is cycled.
Sensor LEDs