3
Periodic Inspection
● Periodic inspections are conducted periodically about
once a year.
● In the periodic inspection, check the daily inspection
points and remove each part according to the following
and check the condition of each part.
Philips screwdriver, wrenches, etc.
Required Tool
Check the screws used for each part for damage of the
cross-recess, deformation of the screws, and rust. If any
abnormality is found, replace the screws with new ones.
① Check the screws on the buckle
The screws (3 locations) on the back of the
buckle should not be missing or loose.
Buckle
③ Check the lower cover fixing screws
Remove the top cover from the frame.
Top Cover
5
If any issues are found during inspection,
immediately discontinue the usage and contact
sales agent to request service.
Be sure to tighten the screws by hand.
The plastic part may be damaged if power tools
are used.
② Check the upper cover fixing screws
Remove the head cushion and check the
upper cover fixing screws and washers (2
locations) are not missing or loose, and
then remove the screws.
After checking the lower cover fixing screws
[2 locations ] are not loose, and then
remove the screws.
Caution