PROGRAMMING OPTION DEFINITIONS:
Restoring factory settings: All factory default settings are restored (see program
0
menu). User password becomes <1-0-1-0> and master password becomes <1-0-
1-0-1-0>.
Individual use or locker mode: Factory default is individual mode. Individual use
mode allows one 4-digit code to be entered that would remain the same code for one
user. Locker mode is for multiple users whereby each user walks up to an open miniK
10 and enters in their own unique code to close the lock and then to open it again.
When open, next user enters in a new code, etc.
Audible volume control: All audio warnings can be turned off if mute operation
is selected (except warning beeps)
Penalty operation: Prevents tampering of lock by unauthorized people. Lock is
blocked for 5 minutes if wrong password is entered three times consecutively.
Factory default is that this feature is not active.
User code reset : Sets user factory default to <1-0-1-0-1-0>.
Service password: Lock can be opened with service password if user password
is forgotten. Factory service default password is <1-0-1-0-1>. No programming
features can be accessed with service password. Factory default is that this feature
is not active.
Closing modes: Factory default - miniK 10 does not require a password to lock. The
other option is it can require a password to lock.
Door open warning: After door is open for one minute, lock gives an audible
warning to user with 8 beeps every 5 seconds to notify user that the door has
been left open.
Resetting user password: If the lock is opened with service password (and
service password is active), user password can be reset. (see program #5 on
service passwords). Factory default is that the service password access does
not allow the user password to be reset (only opens up the lock).
Blocking the lock: If lock opened with service password, it can be blocked from
further user password access.This would. insure service password is only used
to access locks for emergency lockouts. Master password access would then be
required to set up user password again (0-1 Factory default reset). Factory default
is that this feature is not active.
LIGHT AND AUDIO NOTIFICATION:
Password is accepted:
Wrong password:
Low battery:
Lock is open:
CHANGING THE BATTERY:
Lock operates on a 3V lithium coin cell CR2450 battery located on back
side of device. Remove screw located on cover of battery and replace it
with new battery. Battery life is up to 10 years. The red LED light blinks 5
times after each operation when battery is low and it is possible to open.
.
Green LED lights with two repeated audio warnings
Red LED lights with four repeated audio warnings
Red LED lights blink 5 times after each operation
1 minute after door is opened, lock gives audible
warning 8 times every 5 seconds