2.
Site Preparation
Provide drainage, potable water supply and electrical power to within 6 feet (2m) of ice machine
in accordance with local and national codes. Outdoor installation is not recommended and will
void warranty.
2.1
Installation site requirements
208 V –5% to 230 V +5%
Electrical
➊
§ This appliance should be permanently connected by a qualified person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
H_C1010/1410(A/W)BT 208-230/60
Requires a 15A dedicated circuit.
H_E1010/1410(A/W)HS 230/50
‡
H_E710A, H_E1010A/W requires 15A dedicated circuit 1.50 mm
must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable Water Supply
10 psi to 70 psi (69 kpa to 483 kpa)
§ This equipment is to be installed with adequate backflow protection to comply with applicable federal, state, and
local codes
Condenser water supply for water-cooled systems
10 psi min.; 150 psi max. (69 kpa min.; 1034 kpa max.)
20 F to 90 F (–7 C to 32 C)
1.5 gallons (5.68 liters) per minute
Drains:
3/4" Barb for silicone drain, 3/8" push-to-connect for chassis drain
➍
Minimum 8" radius on silicone drain line. The drain line from the ice machine must have at least 1/4" per foot (6,4
mm/0,3 m) pitch
BIN • TOP-MOUNT
➍
3/8"
drain must be
used
‡
➋
(3/8" push-in connection, 3/8" OD tubing required)
chassis
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
➌
3/4" MPT x 1" slip
➍
1" Stand pipe/Drain
➋
➌
➊
➍
1/4"
1'
WARNING!
H_D710ABT 115/60
H_E710ABT 115/60
H_E1400(A/W)HS 230/50/1-20
2
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
45 F to 90 F (7 C to 32 C)
➌
(1/4" FPT inlet, 1/4" FPT outlet)
Horizon 710/1010/1410
Minimum 8"
radius
H_C1010A/W
NEMA
6-15
H_C1410A/W
NEMA
6-20
H_D710A
NEMA
5-15
(Requires a 15A circuit)
‡
‡
2
wire. Plug
5