- ページ 10
製氷機 Follett Horizon Elite HMD1010RJSのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Follett Horizon Elite HMD1010RJS 17 ページ。 Ice machine models with ride technology installation instructions for drop-ins

Connect utilities to louvered docking assembly.
6.1
Water and drain
• Remove access panel if necessary.
• Install drain line
➊
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Rough-in ice machine potable water
➋
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Apply Petrogel to barbed drain fitting
• Replace access panel.
10
➋
➌
➊
.
➌
remote condensing
External connections
6.2
Refrigerant
➊
• Braze supplied expandable refrigerant
lines in place
➊
DROP-IN • RIDE Technology
6