- ページ 8

製氷機 Follett Horizon HCD1400NVSのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Follett Horizon HCD1400NVS 16 ページ。 With remote air-cooled condensing unit
Follett Horizon HCD1400NVS にも: マニュアル (8 ページ), マニュアル (8 ページ)

Follett Horizon HCD1400NVS 取付説明書
4.1
Undercounter installation requirements Horizon 1000 & 1400 series
Access panel/
door on counter
DOCKING STATION
• Position and screw louvered docking assembly to the bottom of counter inside of access
panel/door min. of 1.75" (45mm) from the front edge of the cross brace
• The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
• There must be no lip or edge that would hinder the icemaker from sliding in or out of the
louvered docking station
• Icemaker must be installed facing forward as shown for service accessibility
8
Top View
1.75" (45mm) min.
24.5" min.
(623mm)
21" min.
(534mm
remote condensing
No Lip
VISION • SATELLITE-FILL