Set‐up Guide
Connections
• Feed handpiece from blaster into work chamber
• Attach vent hose to back by slipping Quicknut
over hose, working the hose over the nipple, 
then hand tighten Quicknut onto fitting.
• Connect clear tubing from air dryer to blaster 
inlet air connector
• Connect black tubing from air dryer to inlet air tee fitting
• Connect shop air using a ¼" Industrial Shape Quick‐Disconnect 
(customer supplied).  Example: Foster 3 Series SG1513 or McMaster 
Carr 6536K38
• Connect power source to ProCenter Plus
• Connect blaster power cord to ProCenter Plus
HAND‐
PIECE 
HOSE
POWER 
CORD
AIR 
FROM 
DRYER
TO AIR 
DRYER
Install Air Dryer
The air dryer unit is preassembled and 
only requires mounting to the 
ProCenter Plus and connection of air 
hoses.
• Locate screw holes and position air 
• Raise dryer cartridge to facilitate 
• Connect air hoses
Blow‐Off Gun
Clean any powder residue from the part with 
a quick blast of air.  
• Grasp the gun as shown.  
• Apply pressure with your thumb to direct 
Warning: ProCenter Plus 
outlets are designed to 
The more the tip is bent, the greater the 
supply power for blasters 
volume of air released.
only and should not be 
used for operating other 
equipment.
Air Pressure Regulators
BLASTER
POWER 
There are two air regulator controls on the 
CORD
electronics box located on back of the unit.
• Air Purge: regulates flow to the air jets; 
VENT 
HOSE
SHOP 
AIR
• Blow‐Off: sets air pressure on the blow‐off 
The air pressure regulators are preset at the 
Before you set up and 
operate your Comco 
factory for reasonable air flow and should 
blaster, read and follow 
not require adjustment with the demands 
the safety instructions in 
of normal production.
your Maintenance Manual.
dryer on side of ProCenter Plus
driving screws
a blast of air.  
prevents abrasive from accumulating in 
front of the work chamber.
Note: There should always be air flowing
out of the air jets
gun