- ページ 9

ディスペンサー Follett C50T5A/WのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Follett C50T5A/W 13 ページ。 Ice and water dispenser
Follett C50T5A/W にも: 操作、サービスおよび部品マニュアル (17 ページ)

Follett C50T5A/W インストレーション・マニュアル
H25T5A/W mounting dimensions
1.0625"
27 mm
wall stud
2.3125"
59 mm
44.25"
1124 mm
support angle
9.5"
241 mm
Wall Bracket
9.5"
utility cutout
241 mm
3.40625" (87 mm)
4.59375"
125 mm

Installing remote icemaker

See R5A/W Installation Manual (Form #206428) for critical installation instructions for
!
remote icemakers. Failure to comply with these instructions will result in poor
performance and void warranty.
When 10 feet (3 m) or less of ice transport tube is required to carry ice from evaporator port to dispenser, the unit will be
shipped with one end of tube already installed in mounting bracket of dispenser. For runs that exceed 10 feet (3 m) the
tubing is not mounted and requires a different installation procedure. Refer to appropriate section below for your specific
installation.
Units shipped with standard 10 feet (3 m) of ice transport tube
1. Position icemaker in desired location.
2. Refer to R5A/W Installation Manual (Form #206428) packed with icemaker for installation instructions, restrictions on
ice transport tube run and ventilation requirements for remote icemakers.
Units shipped with more than 10 feet (3 m) of ice transport tube
1. Remove top and rear access panel from dispenser.
2. Run end of ice transport tube with 3/16" (1.9 mm) hole through right hand knockout in back of dispenser or through
counter into bottom of dispenser, being careful to avoid any
bends with less than a 6" (15.2 cm) radius.
3. Insert tube in internal chase in rear inside corner of dispenser
(right side as you face rear of dispenser) and push up into
storage area.
4. Push 3/16" (5 mm) hole near end of tube into engaging pin on
ice tube bracket (see drawing at right).
5. Install supplied insulation to run of transport tube required for
your site, leaving approximately 2" (5.1 cm) of tube exposed
at free end.
6. Check that insulated tube runs continuously uphill to
dispenser with no dips.
20.625"
524 mm
filler strip
16"
3/8" (10 mm)
406 mm
fasteners (6 sites)
25.625"
651 mm
3.5"
89 mm
11.4375"
1.28125"
291 mm
33 mm
(Models C25R5A/W, C50R5A/W, H25R5A/W, H50R5A/W)
H50T5A/W mounting dimensions
1.0625"
27 mm
2.3125"
59 mm
48.25"
1226 mm
support angle
11.5"
292 mm
Wall Bracket
11.5"
292 mm
3.40625" (87 mm)
4.59375"
125 mm
Capillary
tube
Ice tube
bracket
7
ICDI220
20.625"
524 mm
filler strip
wall stud
16"
3/8" (10 mm)
406 mm
fasteners (6 sites)
29.625"
752 mm
utility cutout
3.5"
89 mm
11.4375"
1.28125"
291 mm
33 mm
1"
2.5 cm
Engaging pin
3/16"
1.9 mm
Ice
hole in
tube
Back wall
ice tube