SPECIFICATIONS
GENERAL SPECIFICATIONS
Display : 3-5/6 digits 6000 counts LCD display(s)
Update Rate : 5 per second nominal
Polarity : Automatic
Low Battery : Below approx. 2.4V
Operating Temperature : 0°C to 40°C
Relative Humidity : Maximum relative humidity 80% for temperature up to
31°C decreasing linearly to 50% relative humidity at 40°C
Altitude : Operating below 2000m
Storage Temperature : -20
Temperature Coefficient : nominal 0.15 x (specified accuracy) /OC @
o
o
(-20
C to 60
C), or otherwise specified
Sensing : Average sensing for ACD-15 PRO; True RMS sensing for ACD-15 TRMS PRO
Safety : Meets EN61010-1:2001; EN61010-2-032:2002), UL3111-2-032(1999):
Category III 600 Volts ac & dc
Transient protection : 6.5kV (1.2/50μs surge) for all models
Pollution degree : 2
E.M.C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995), and EN61000-4-
3(1996) In an RF field of 3V/m:
Capacitance function is not specified.
Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
Overload Protections :
ACA Clamp-on jaws : AC 2000A rms continuous
+ & COM terminals (all functions) : 600VDC/VAC rms
Power Supply : standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2
Power Consumption : 2.2mA typical for ACD-15 PRO; 2.8mA typical for ACD-15
TRMS PRO
APO Timing : Idle for 3 minutes
APO Consumption : 40μA typical on all model functions except that 230μA
typical on ACD- 15 TRMS PRO voltage & current functions
Dimension : L224mm X W78mm X H40mm 224 x 78 x 40mm (8.8 x 3.1 x 1.6")
Weight : 220 gm approx (7.7 oz)
Jaw opening & Conductor diameter : 45mm max
Accessories : Test leads (pair), batteries installed, user's manual, & soft carrying
pouch
o
o
C to 60
C, < 80% R.H. (with battery removed)