- ページ 7

トランスデューサー Daiichi Electronics HSQT2-93AのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Daiichi Electronics HSQT2-93A 16 ページ。 High speed multi power line transducer

2.3 Option
Item
The countermeasure against
hydrogen-sulfide (H
S) gas
2

2.4 Specification and performance

Item
Compliant standard
CE compliant
directive
Safety
Influence of
temperature
Update time of
measured value
Response time
Ripple of output
Power-supply
temporary-blackout
allowed time
Power-supply rush
current
Insulation resistance
Voltage tests
(Withstand voltage)
Impulse voltage tests
(Lightning impulse
withstand voltage )
Vibration
Shock
Environmental conditions
:Hydrogen sulfide, 1ppm,40℃,80%RH, Air supplying amount, Less than 1000L/H
Electrical measuring transducers for converting a.c. electrical quantities to analogue or
digital signals. JIS C 1111:2006 [ IEC 60688:1992,Amendment 1 (1997),Amendment2 (2001) ]
Electro-magnetic compatibility directive (EMC Directive) 2004/108/EC
(Only auxiliary supply DC24V specification conforms.)
Low voltage directive (LVD) 73/23/EEC (Only auxiliary supply DC24V specification conforms.)
JIS C 1010-1:2005 (IEC 61010-1:2001)
Measurement category Ⅲ (The category to the measurement performed with fabric equipment)
Maximum use voltage, 300V
Degree of contamination, 2 (Usually, the grade which only contamination of non-conductivity
causes. However, temporary conductivity, which originates in dew condensation depending
on the case occurs.)
Use group Ⅰ (For indoors. It is used in the place where the equipment is careful and is
dealt with under the conditions generally seen at a laboratory, a factory, etc.)
10~35℃ :Inside of class index.
0~45℃ :Within 2 times of class index.
-10~+55℃:Within 3 times of class index.
5ms
Time within ±1% of final constant value, when step input is charge.
[ A,V,W,var ] With no moving average:Less than input one cycle +10ms.
2 times of moving average:Less than input one cycle +15ms.
3 times of moving average:Less than input one cycle +20ms.
[ Hz ] Less than 1 second.
Less than 1% peak-to-peak to output span.
20ms
AC110V:Below 5.5A (Time constant:below 10ms)
AC220V:Below 11.0A (Time constant:below 10ms)
DC110V:Below 4.0A (Time constant:below 10ms)
DC24V :Below 6.5A (Time constant:below 10ms)
Between electric circuit and case (earth).
Between input and output and auxiliary supply.
Between analog output non-insulates (minus common).
Between electric circuit and case (earth).
Between input and output and auxiliary supply.
Between analog output non-insulates (minus common).
Between electric circuit (analog output excludes) and
case (earth).
Between input and auxiliary supply (output is earth
connection).
JIS C 60068-2-6:1999 (IEC 60068-2-6:1995).
Vibration frequency range:10~55Hz,Vibration amplitude:0.15mm(Single-sided amplitude ),
Number of sweep cycles:10 times
JIS C 60068-2-27:1995 (IEC 60688-2-27:1972)
Peak acceleration:500m/s
Specification
Specification
2
6
Above 50MΩ at DC500V
AC2210V (50/60Hz) 5 seconds
5kV 1.2/50μs
Positive and negative polarity,
for each 3 times
Q-208-081