- ページ 2

コントローラー Amroad ID5101のPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。Amroad ID5101 4 ページ。 Home station
Amroad ID5101 にも: インストレーション・マニュアル (20 ページ)

Amroad ID5101 クイック・インストール・マニュアル
IO Circuit and Application
The ID5101, Video Indoor Station, provides 8 Input ports and 4 Output port for your house
to set up Home Safety and Security; you may refer the following examples for each
application.
Please connect the adapter which comes with the package to the DC +12V as below and
then connect your end devices according to your requirement.
LIGHTING
The illustration (diagram) shows you how to use the first GPIO connector and wire to
connect Adapter and two Relay Boards for Lighting Control.
ALARM
The illustration (diagram) shows you how to use the first GPIO connector and wire to
connect DC power and Relay Board for ALARM device.
NOTE:
Please use wire
tape to seal
unused wire to
isolate the wire.
800-0000007-00-00
Wire connection for
Lighting
2
Magnetic Switches
Both diagram and photo of Magnetic Switch installation show you how to use the second
GPIO connector to connect with Magnetic Switches, and you can connect up to four
magnetic switches accordingly based on the diagram or photo.
CO Detector, Emergency Button... and Door Bell Button
The status of the following safety devices will be shown on the main screen. The following
diagrams show you how to use 3rd GPIO connector to connect CO Sensor, Emergency
Button, and Gas Detector.
CO Detector
Emergency Button
NOTE:
The second GPIO
connector is used to
connect up to four
Magnetic Switches.