- ページ 5

エアコン Daikin Altherma EAVX16S18DA6V(G)のPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。Daikin Altherma EAVX16S18DA6V(G) 16 ページ。

Daikin Altherma
EAVX16S18DA6V(G) 操作マニュアル
Item
Restriction: Only displayed if a room
Room
thermostat is connected to the indoor unit.
Set the room temperature.
Shows the applicable symbol for your main
Main zone
zone emitter type.
Set the leaving water temperature for the
main zone.
Restriction: Only displayed if there are two
Additional zone
leaving water temperature zones. Shows
the applicable symbol for your additional
zone emitter type.
Set the leaving water temperature for the
additional zone (if present).
Shows the applicable symbol for your unit.
Space heating/
cooling
Put the unit in heating mode or cooling
mode. You cannot change the mode on
heating only models.
Restriction: Only displayed if a domestic
Tank
hot water tank is present.
Set the domestic hot water tank
temperature.
Gives access to user settings such as
User settings
holiday mode and quiet mode.
Displays data and information about the
Information
indoor unit.
Restriction: Only for the installer.
Installer settings
Gives access to advanced settings.
Restriction: Only for the installer.
Commissioning
Perform tests and maintenance.
Change the active user profile.
User profile
Turn heating/cooling functionality and
Operation
domestic hot water preparation on or off.
3.2.3

Setpoint screen

The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Example:
▪ Room temperature screen
▪ Main zone screen
▪ Additional zone screen
▪ Tank temperature screen
d
c
+
a2
b2
e
d
d
e
a1
b1
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
Item
Minimum temperature limit
EABH/X16DA+9W + EAVH/X16S18+23DA6V+9W
Daikin Altherma – Low temperature split
4P556068-1 – 2018.10
Description
Description
a1
Fixed by the unit
a2
Restricted by the installer
Item
Maximum temperature limit
Current temperature
Desired temperature
Submenu
3.2.4

Detailed screen with values

a
b
a
Settings
b
Values
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Confirm changes and proceed.
3.3

Space heating/cooling control

3.3.1

Setting the space operation mode

About space operation modes
Depending on your heat  pump model, you have to tell the system
which space operation mode to use: heating or cooling.
If a ... heat pump
model is installed
Heating/cooling
The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
Heating only
The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.
To tell the system which space operation to use, you can:
You can...
Check which space operation mode is
currently used.
Set the space operation mode permanently. Main menu
Restrict automatic changeover according
to a monthly schedule.
To set the space operation mode
1 Go to [4.1]: Space heating/cooling > Operation mode
2 Select one of the following options:
▪ Heating: Always heating mode
▪ Cooling: Always cooling mode
▪ Automatic:
The
operation
automatically based on the outdoor temperature.
Restricted according to the operation mode
schedule.
3 Operation
Description
b1 Fixed by the unit
b2 Restricted by the installer
c
Measured by the unit
d
Turn the right dial to
increase/decrease.
e
Turn or press the left dial to
go to the submenu.
Then...
Location
Home screen
mode
changes
Operation manual
5