AS5601-SO_RD_ST
Operation Manual
2
2.4.3 I

C Mode

Using the I²C Interface, all functions of the AS5601 can be configured and permanently
programmed. Additionally the output and a raw angle (unmodified value) can be read from the
output registers.
Figure 6:
Using the reference module in I2C Mode
µC
3

AS5601 Configuration

All options to configure the AS5601 are shown below. The AS5601 operates with a default
configuration if no configuration was programmed.

3.1 Programming the output range

To adjust a custom angle to the full output range or to modify the Zero Position of the device, the
AS5601 must be programmed. Following options are available:
Programming start and stop position with I
Programming an angular excursion with I
Follow the step-by-step instructions in the AS5601 datasheet for one of the above programming
options.

3.2 Programming a configuration

A configuration must be written using the I2C interface. The Burn Setting command (Write 0x40 into
register 0xFF) can be used to permanently program a configuration.