User Manual
10.
Each time KHG reboots, it will attempt to obtain time to the network time server. If not obtainable from the
network server, KHG will use its internal clock. If the internal clock also fails, the date and time will display
"Time N/A".
11.
Due to strict regulation of mailing battery on the aircrafts, KHG will only be shipped without internal battery.
For instructions how to obtain and install internal battery, please contact your dealer.
12.
When positioning the KHG, the intake tube must be within 100cm and the KHG must not be positioned
below the water surface of the location of intake tube water source.
13.
To prevent siphoning of tank water via KHG, the Reaction Chamber purge tube and the Sodium Bicarbonate
tube must not be immersed into the tank.
14.
KHG intake tube shall not be positioned to the bottom of the tank, and should be protected to prevent debris
from entering into the intake tube and result in blockage in the tubing.
15.
The "C" version of the KHG comes with auto supplementation of Sodium Bicarbonate. To use this feature,
please prepare your Sodium Bicarbonate solution by mixing 65 grams of sodium bicarbonate powder per
one liter of water. Please keep the error tolerance to within 5%.
16.
We would strongly recommend to keep KHG in a protected container away from saltwater splashes. Please
contact your dealers for details.
17.
Please do not attempt to open the cover of the KHG other than normal cleaning along the path of the liquid
tubings. Warranties are void if the KHG body cover has been opened.
18.
Please do not apply lubricants to the heads of the Sodium Bicarbonate pump, Tank Water Intake Pump and
Waste Water Purge Pump. Use only dry paper towels to wipe clean if necessary.
19.
KHG Reagent Pump should be taken apart for lubrication every 6 months. Use only Molykote EM-30L
Grease for lubrication. Other lubricants are strictly prohibited. The tubing for the peristaltic motor should be
replaced at least once a year.
20.
Complete system test will be performed on every KHG during factory pre-shipment tests. Salt residue may
be present in the tubing upon purchase. The residue will be purged out during the initiatial setup.
21.
KHG maybe customized according to your need. Please contact your dealer if you deemed necessary.
Please do not attempt to alter KHG by yourself or the warranty will be void.
Page14