- ページ 2

錠前 AMSEC PB3のPDF 使用方法をオンラインで閲覧またはダウンロードできます。AMSEC PB3 4 ページ。 5-button electronic lock

AMSEC PB3 使用方法
Each AMSEC safe is professionally hand-crafted with quality materials and is equipped with a
precision-quality, high-security combination lock. To become familiar with the lock, operate the
lock (as outlined below) several times before closing the door and locking the safe.
OPERATING INSTRUCTIONS – AMSEC 5-BUTTON ELECTRONIC LOCK -
Quick Reference
To Open the Lock on the factory code:
Press 1-2-3-4-5 and then turn knob clockwise about 90 degrees.
To Set the Primary Code:
Lock the safe OPEN. Press the change button once; then enter 5 keystrokes for the new
primary code. Test the new code.
To Set the Backup Code:
Lock the safe OPEN. Press the change button twice; then enter 8 keystrokes for the new
backup code. Test the new code.
To Turn the Sound of the Beeper Off:
Lock the safe OPEN. Press the change button three times; then press button number 1. To
return the beeper to On, Repeat the same steps.
NOTICE:
The PB3 Digital Lock has Two (2) operating combinations, a Primary Code for everyday use,
and a Backup Code for you to use in the case you forget or make an error changing your
Primary Code. ALL LOCKS HAVE THE SAME BACKUP CODE. To insure security, you MUST
set a unique Backup Code and store it in a secure location (not inside the safe).
Detailed Instructions
The AMSEC PB3 lock is an electronic safe lock. This lock provides quick access to a security
container with high reliability and little effort. For maximum security, it is recommended that the
PB3 be anchored to a permanent surface.
Operating Information
¾ There are two programmable "codes" in the lock; a "Primary" code that requires five (5)
keystrokes, and a "Backup" code that requires eight (8) keystrokes.
¾ A "Keystroke" can be one button, or two buttons pushed simultaneously.
¾ The Buttons are numbered 1 thru 5 starting at the left.
¾ The "Primary" code is for everyday use. The "Backup" code is provided so the user can have a
means to access the safe in the event they forget their Primary Code. The Backup Code should
be set to some unique combination, and kept in a secure location (not inside the safe).
¾ The "Factory" Primary code is 1 – 2 – 3 – 4 – 5.
¾ The Backup Code is not kept at the factory. Every PB3 lock comes with the same Backup
Code. Please set you own unique Backup Code to insure security.
¾ The Factory Default Backup Code is 5 – 4 – 3 – 2 – 1 – 5 – 4 - 3. The consumer should change
this code to provide optimum security.
MODEL PB3