- ページ 25

冷蔵庫 Electrolux 725239のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Electrolux 725239 34 ページ。 Vertical refrigerators
Electrolux 725239 にも: ユーザーマニュアル (18 ページ)

Electrolux 725239 マニュアル
Model
V2MPBTHC
V2MPTNBTHC
V1MPTNBTHC
V1MPBTHC
V1MPTNBT
V1MPBT
V2MPBT
V2MPTNBT
A.13 Electrical connection for appliances with plug
• To connect to the power supply, insert the power cable plug in the corresponding mains socket, first making sure:
– the socket has an efficient earth contact and the mains voltage and frequency match that given on the dataplate. In case of
any doubts regarding the efficiency of the earth connection have the system checked by specialised personnel.
– the system power supply is arranged and able to take the actual current absorption and that it is correctly executed according
to the regulations in force in the country of use.
• The plug must be accessible after positioning the appliance in the place of installation.
• The plug must be in a position always visible to the operator performing the intervention during maintenance operations.
A.14 Electrical connection for appliances with cable without plug
• The connection point has an efficient earth contact and the mains voltage and frequency match that given on the data plate. In
case of doubts regarding the efficiency of the earth wire, have the system checked by specialised personnel.
• The appliance must be permanently connected to the power supply, respecting the polarities:
– brown/black
2
/gray
– yellow/green: earth
– blue: neutral
• An H05VV-F type power cable (code 60227 IEC 53) is used for the permanent connection to the mains; in case of replacement,
use a type with at least these characteristics. When replacing the cable, the earth wire must be kept longer than the live and
neutral wires.
• The differential thermal-magnetic switch must be lockable in the open position in case of maintenance.
• If using a plug, it must comply with the national installation rules. The plug must also be:
– accessible after the appliance has been positioned
– in the place of installation;
– in a position always visible to the operator performing the intervention during maintenance operations;
A.15 Positioning
• Install the appliances, taking all the safety precautions required for this type of operation, also respecting the relevant fire-
prevention measures.
• For the choice of remote condensing unit refer to the unit recommended by the Manufacturer, given on the equipment technical
sheet.
• In case of extraordinary size of the remote condensing unit refer to the technical sheet for the refrigerating capacity data or
consult the Manufacturer's website or Local Service Center/ Agency authorized by the Manufacturer.
• In appliance with R-744 as refrigerant, a pressure relief device shall be installed in the high pressure side of the refrigeration
system between the motor-compressor and the gas cooler. There shall be shut off devices or other components except piping
between the motor-compressor and the pressure relief device that could introduce a pressure drop.
• The pressure relief device shall be mounted so that any refrigerant released from the system during its operation can not cause
harm to the user of the appliance. The aperture shall be located so that it is unlikely to be obstructed in normal use.
• The installed pressure relief device shall have no provisions for setting by the end user.
• The pressure setting of the installed pressure relief device shall be no higher than the design pressure of the high-pressure side.
• For any fine-tune setting to the electronic valve parameters please refer to the service manual on the website.
• In case of "Marine" models, the appliances must be fixed to the floor.
• Prevent the areas where the appliance is installed to be polluted with corrosive substances (chlorine, etc.). The manufacturer
declines any liability for corrosive effects due to external causes.
A.16 Wall fixing
• When installing the glass door appliances with high feet make sure to fix the anti-tipping cables to it.
To fit proceed as shown in the paragraph E.6 Fitting anti-tipping cables on glass door models (2 module) with feet or wheels
2.
present only in appliances with three-phase power supply
2M Freezer 2 full doors R290
2M 2T refrigerator/freezer 900+300L R290
2M 2T refrigerator/freezer 600+600L R290
1M 2T refrigerator/freezer 300+300L R290
1M freezer full door R290
1M freezer glass door R290
1M 2T refrigerator/freezer 300+300L R404a
1M freezer full door R404a
1M freezer glass door R404a
2M Freezer 2 glass doors R404a
2M 2T refrigerator/freezer 900+300L R134a/R404a
2M 2T refrigerator/freezer 600+600L R134a/R404a
2
: phase
Description
Maximum impedance
permitted (Ohm)
0,307 Ohm
0,396 Ohm
0,390 Ohm
0,3031 Ohm
0,2976 Ohm
0,2733 Ohm
25