- ページ 8
冷蔵庫 Electrolux 725239のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Electrolux 725239 18 ページ。 Vertical refrigerators
Electrolux 725239 にも: マニュアル (34 ページ)
In case of a significant anomaly (e.g. short circuits, wires coming out of the terminal block, motor breakdowns, worn electrical cable
sheathing, etc.) the operator for normal appliance use must:
• immediately deactivate the appliance.
A.15 Appliance maintenance
• The inspection and maintenance intervals depend on the actual appliance operating conditions and ambient conditions
(presence of dust, damp, etc.), therefore precise time intervals cannot be given. In any case, careful and periodical appliance
maintenance is advisable in order to minimise service interruptions.
• It is advisable to stipulate a preventive and scheduled maintenance contract with the Customer Care Service.
• Put the appliance in safe conditions before starting any maintenance operation.
• To guarantee appliance efficiency and correct operation, periodical maintenance must be carried out according to the
instructions given in the manual.
A.16 Maintenance intervals
It is advisable to carry out the checks with the frequency given in the following table:
Maintenance, inspections, checks and
cleaning
Ordinary cleaning
• general cleaning of appliance and surrounding
area
Mechanical protection devices
• check their condition and for any deformation,
loosening or removed parts
Door frame and Gasket
• Check the integrity status of the door frame
and door gasket.
Check the cleanliness of the door frame and
door gasket.
Replace in case broken.
Control
• check the mechanical parts, for cracks or
deformations, tightening of screws: check the
readability and condition of words, stickers
and symbols and restore if necessary
Appliance structure
• tightening of main bolts (screws, fixing
systems, etc.) of appliance
Safety signs
• check the readability and condition of safety
signs
Electrical control panel
• check the electrical components installed
inside the electrical control panel. Check the
wiring between the electrical panel and
appliance parts
Electrical connection cable
• check the connection cable (replace if
necessary)
General appliance overhaul
• check all components, electrical equipment,
corrosion, pipes...
1.
The appliance is designed and built for a duration of about 10 years. After this period of time (from commissioning) the appliance must undergo a general
inspection and overhaul.
B
APPLIANCE AND MANUFACTURER'S IDENTIFICATION DATA
The data plate gives the product identification and technical
data.
8
Frequency
• Daily
• Yearly
• Monthly
• Yearly
• Yearly
• Yearly
• Yearly
• Yearly
1
Every 10 years
Responsability
• Operator
• Service
• Service
• Service
• Service
• Service
• Service
• Service
• Service