Step 3. Install the Mounting Brackets
The mounting brackets are secured using hardware that slots into the rails on top of the housing.
Slide the bolts into the rail, position the brackets over the bolts, and tighten the nuts onto the bolts.
Z Bracket Installation
Point the brackets DOWN for threaded rod/suspended mounting or UP for direct ceiling mounting.
If the brackets are installed facing UP, position the bend in the bracket flush with the edge of the
screen housing.
Straight Bracket Installation
Install the brackets a minimum distance apart to prevent instability after hanging the screen
housing. The brackets may be positioned off-centered as needed to fit the ceiling structure.
Minimum Bracket
Size
Separation
100"
110"
120"
130"
DOWN
73.20"
78.97"
84.88"
90.71"