- ページ 10

パイプクリーナー Drain Master CE50のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Drain Master CE50 15 ページ。 Electric drain cleaner

Electric Drain Cleaner - CE50
If the cutting tool becomes lodged and the cable is still rotating, the cable will start to
twist – release the foot switch to stop the motor immediately to help prevent
damaging the cable (the cable drum may rotate backwards somewhat as tension in the cable releases).
Ensure that the tool and/or cable is
obstruction is unknown, use the Boring Bulb cutter to explore the obstruction and, if possible, retrieve a piece
to inspect. Once you can see the cause of the obstruction, select the appropriate tool for the job. Run the
smallest available tool through the blockage to allow the backed up water to flow and carry away the debris
as the drain clears.
Once the drain is flowing, more appropriate tools can be used on any remaining blockage. Keep in mind
that the largest tool used should be no bigger than the drain inside diameter, minus 25mm (1").
If properly used, the machine will not damage a drain that is in good condition and properly designed,
constructed, and maintained. However, if the drain is in poor condition or has not been properly designed,
drain clearing work may damage it. If possible, visually inspect the drain quality before operation.
Once the drain is flowing, more appropriate tools can be used on any remaining blockage. Keep in mind
that the largest tool used should be no bigger than the drain inside diameter, minus 25mm (1").
If properly used, the machine will not damage a drain that is in good condition and properly designed,
constructed, and maintained. However, if the drain is in poor condition or has not been properly designed,
drain clearing work may damage it. If possible, visually inspect the drain quality before operation.

Feeding the Cable

Only one person should operate the machine. Do not operate the machine with one person
controlling the cable and another person controlling the foot switch. This can cause the
cable to kink, twist, and break, which can also lead to serious personal Injury.
Place the motor switch in the "FOR" position.
Grasp the cable with gloved hands and start feeding the cable into the drain as far as it will go.
Press the foot switch to activate the cable drum, and continue feeding the cable into the drain.
If the cable becomes lodged (for example: in a narrow part of the drain, in a drain trap, etc.), stop feeding
the cable and allow the cable to work past the obstruction.
If the cable still will not pass the obstruction, release the foot switch, then pulse it to try and clear the
obstruction.
Once the cable is free of the obstruction, press the foot switch and continue feeding.
The motor switch controls rotational direction of the cable drum only. Do NOT use the "REV" position
to retract the cable. Use "REV" only momentarily for relieving pressure or
The warranty may be voided if the cable is damaged through excessive twisting, or if the
obstruction. •
cable drum is run in reverse long enough to unwind cable.
E&OE
dislodged
before continuing to use the machine. • If the cause of the
© 2018 Drain Master
untangling cable from an
10