8.2.
Utilities that can be activated in parameter programming
•
All the output relays can be sequentially activated in order to check all the outputs from the power
board
do1, do2, ... (dox=RLx on the EWD)
Enter in parameter programming and choose TEST from the menu. The following page will be
o
displayed.
The button P1 acts as main switch: if it is released, the test stops.
o
Each time the P2 button is pressed, the next relay is activated
o
If the P2 button is kept pressed, the relays are sequentially activated.
o
If one of the probes is detecting the same temperature of the ntc probe (BOARD temperature), the
meanings are the following:
1) Probe in short circuit
2) Probe not connected (for example Prb on a lev. A oven)
3) Probe at the same temperature of the ntc probe
11. Selection of the language for the recipe menu (lev. A)
It is possible to select a language for the menu of the recipes. To select the language, set parameter LanG
to the correct value for the desired language (see the relevant parameter list).