- ページ 7
投影スクリーン Draper 145001のPDF 説明書 インストールと操作をオンラインで閲覧またはダウンロードできます。Draper 145001 7 ページ。 220v electric projection screen
Ultimate Access E and V 220V
Section 13 - Wiring Diagrams: 220V Standard Motor
Please Note: Do not wire motors in parallel.
Internal LVC-IV - Single or Multiple Projection Screen Wiring Diagram
INTERNAL SCREEN WIRING
Green/Yellow
(Motor Ground)
Brown (Up)
Black (Down)
Blue (Common)
GND
N
To
L1
230 VAC
Line
External LVC-IV - Single or Multiple Projection Screen Wiring Diagram
Internal Screen Wiring
Blue (Common)
Brown (Up)
Black (Down)
Green/Yellow
(Motor Ground)
N
To
230 VAC
L1
Line
GND
Single Station Control
CE Approved
Internal Screen Wiring
Blue-220V (Common)
Brown-220V (Up)
Black-220V (Down)
Green/Yellow (Motor Ground)
Control
switch
Dashed wiring
by installer.
220V,
50 Hz.
Internal LVC-IV - Single or Multiple Projection Screen Wiring Diagram
Green/Yellow (Ground)
Red-to screen (directional)
Brown-to screen (directional)
White -Common to screen & 230V AC Neutral
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low-voltage wiring by others
Factory wiring
External LVC-IV - Single or Multiple Projection Screen Wiring Diagram
White-Common to screen & 230V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Green/Yellow (Ground)
Location of key
operated 0n-off
switch if furnished.
Dashed wiring by electrician
Low-voltage wiring by others
* These wiring diagrams
are for Ultimate Access
screens with motor on
audience left
, and
(standard)
fabric unrolling from the
back of the roller
.
(standard)
Receiver
Button
Receiver
Button
page 7 of 7
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules.*
RS232/485
Inputs/Outputs
IR Eye Input
*A maximum of six (6)
Low-Voltage
LVC-IV modules can be
linked together.
Trigger
4-28 VDC
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules.*
RS232/485
Inputs/Outputs
IR Eye Input
*A maximum of six (6)
LVC-IV modules can be
Low-Voltage Trigger
linked together.
4-28 VDC
Wall Switch
Wall Switch