Paragon/Series E and V 220V by Draper
Optional Wall
Case Width
Mounting
> 244 and < 457 cm
Bracket
> 457 and < 610 cm
> 610 and < 878 cm
25 mm
Brackets are equally spaced from each
other and each end. For example, if the
case length is 513 cm, then each of the
two brackets will be placed approxi-
73 mm
mately 171 cm from each end (with 171
83 mm
cm between them).
73 mm
83 mm
73 mm
1
/
" (12 mm) dia.
2
3
/
" (9.5 mm) dia.
8
Bottom Closure Removal/Replacement
Removal and replacement of the bottom closure panel
requires two people positioned about 152 cm from each end
of the panel. Closure should be handled as shown in Step 5
below to prevent bowing of the closure during handling.
Before removing
bottom closure, you
must first remove
screws at each end
of case (see drawing
at right).
Screw and washer
Caution: Be sure to replace screws
and washers at each end of case
when replacing closure!
Step 1
Step 2
Step 3
Step 4
Case Dimensions*
No. of
Intermediate
Brackets
<244 cm
0
1
2
3
Tab-Tension
Adjustment Procedure
for Paragon
Draper's Tab-Tensioning System
is factory-set; under normal
circumstances field adjustment is
not required. If you notice wrinkles,
waves or other indications that
tensioning cables need adjusting,
follow these steps:
1 Determine which side requires
adjustment.
2 Secure dowel with one hand.
Caution: Don't touch or bend
viewing surface.
3 Use Phillips-head screwdriver to
depress spring-loaded
adjustment screw. Slowly turn
clockwise to tighten tension or
counterclockwise to loosen
tension. The screw adjusts in ¼
turn increments. Adjust only one
increment (¼ turn) at a time.
4 If problem is not corrected, leave
screen in position for 24 hours to
allow surface material to stretch
into position.
5 If problem still is not corrected,
repeat steps 2 and 3.
Tensioning
Cable
Dowel
Adjustment
Screw
Step 5
See separate Se-
rial Communication-
RS232 Instruction
sheet for enabling
RS232 with the MC1.
www.draperinc.com
203
mm
51 mm
305 mm
35 mm
337
mm
57
57
mm
mm
127
51 mm
mm
51
mm
*Please Note: Optional wall brackets add 4.5 cm per bracket to case
length. Wall mounting bracket hole location is 2.54 cm from end of case.
Please Note: Do not wire motors in parallel.
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Control
switch
Dashed wiring
by installer
Low Voltage and Remote Control
Program LED
Fuse
MC1
(765) 987-7999
*
* - Case support brackets will be evenly spaced along the case
Series E
Viewing
Surface
Wiring Diagrams
Junction box at
left end of screen
Green/Yellow (Motor Ground)
220v,
50 Hz.
220v, 50 Hz.
White or Blue-Common to screen & 110/220V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110/220V AC-Hot
Black-to 110/220V AC-Hot
Green/Yellow (Ground)
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
MC1
White or Blue-Common
Red-to Screen (directional)
Black-to Screen (directional)
Brown-Hot to AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
Page 2 of 2
Varies
Series V
54
Viewing
mm
Surface
Multiple Station Control
Not CE Approved
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Cap off with wire
nut & tape
Red
Blue
Black
Red
Blue
Black
Blue
Red
Black
Dashed wiring
by installer
Internal Screen Wiring
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green/Yellow
(Motor Ground)
To
110/220V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches
24v DC
Internal Screen Wiring
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green 110V/
Green/Yellow 220V
(Motor Ground)
Location of key
operated on-off
switch if furnished
To AC Line