- ページ 2

投影スクリーン Draper RolleramicのPDF 取付・取扱説明書をオンラインで閲覧またはダウンロードできます。Draper Rolleramic 2 ページ。 Electric projection screen

Draper Rolleramic 取付・取扱説明書
Rolleramic by Draper
Rolleramic Mounting Bracket
For suspended mount.
Screens through 14' wide have 2 mounting
brackets; wider screens have 3. Brackets
should be located along case to line up
with supporting beams or studding. Motor
3
6
/
"
8
end bracket must be located 1"-6" to right
of access door. Idler end bracket must
1
3
/
"
8
be located 6"-12" from right end of case.
For wall mount
Failure to mount brackets as directed could
cause case to bow and result in damage
to screen.
Please Note: Mount the case using the two end brackets first. If
a center bracket is provided, mount it last. The center bracket is
designed to prevent sagging of the case, and must be mounted so
that it is level with the others and does not force the screen case
up. Make sure the top of the screen case's bottom board at no
point touches the roller/viewing surface.
Junction box at
left end of screen
To 110-120V Line
Rolleramics over 12' x 12'
have a blue wire lead
instead of a black wire lead
coming from the motor.
Wiring Diagram for Ambassador and Rolleramic
INTERNAL SCREEN WIRING
White (Common)
Red (Down)
Black (Up)
Green/Yellow
(Motor Ground)
To
110-120 VAC
L1
Line
N
GND
Case Dimensions
Rolleramic Wiring Diagrams
Please Note: Do not wire motors in parallel.
Single Station Control
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Dashed wiring
by electrician
Single gang box by others
Control
Min. 4" x 2 1/8" x 1 7/8" deep
switch
Blue
Red
Black
Location of key
operated on-off
switch if furnished
External LVC-IV - Single or Multiple
Low Voltage & Wireless Control
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110V-220V AC-Hot
Black-to 110V-220V AC-Hot
White -Common to screen & 110V-220V AC Neutral
Green/Yellow (Ground)
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
www.draperinc.com
Conduit
connection
1
11
/
"
9
5
/
"
9
1
/
"
2
8
8
9
5
/
"
8
1"-6" from
1
9
/
"
8
Case
access door
¾" thick
Through 12' x 12' 14¾"
Over 12' x 12' 21¼"
Access
Bottom
Door
Multiple Station Control
Junction box at
left end of screen
Red
Black
Red
Black
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
(765) 987-7999
L = W+24" (through 12' x 12')
L = W+30" (over 12' x 12')
Screen
6"-12" from
surface
case edge
Fabric width – W
Bottom board
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Cap off with wire
nut and tape
Blue
Dashed wiring
by electrician
Blue
Blue
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.
Receiver
3 Button Wall Switch
Button
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
IR Eye Input
Low Voltage
Trigger
3-28 VDC
Page 2 of 2
Front
4
5
/
"
8
4" - 4
1
/
"
8
Opening for fabric
Wall Switch
*A maximum of six (6)
LVC-IV modules can be
linked together.