- ページ 5

投影スクリーン Draper Targa XL 220VのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Draper Targa XL 220V 7 ページ。 Electric projection screen

Premier XL
®
Electric Projection Screen
Section 7 - Wiring Diagrams
Please Note: Do not wire motors in parallel.
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Control
switch
Dashed wiring
by installer
* These wiring diagrams are for
220v,
50 Hz.
screens with motor on audience
left (standard), and fabric
unrolling from the back of the
roller (standard).
Connecting Switch
to ILT Motor
Back of
Back of
Wall Switch
Wall Switch
/ Targa XL
®
Multiple Station Control
Junction box at
Not CE Approved
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Cap off with wire
nut & tape
Blue
Red
Black
Red
Blue
Black
Blue
Red
Black
Dashed wiring
by installer
220v, 50 Hz.
Wiring Diagrams—Plug & Play 220V Motor
(Low Voltage Control Built Into Motor)
Single Low Voltage Control
Internal Screen Wiring
Blue (Neutral)
Brown
Green (Ground)
Data Cable
Wall Switch,
RF or IR
Receiver,
or integrated
control system
220V
ILT Data Cable Connection
Back of
Back of
Data Cables to switches or
Wall Switch
Wall Switch
MOTOR
to additional motors
DATA CABLE
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
OR
Back of
Back of
Wall Switch
Wall Switch
Dry Contacts
MOTOR
220V
220V Motor with Internal
Low Voltage Controller
Single Low Voltage Control
Dashed wiring
by electrician
Wall Switch,
RF or IR
Receiver,
or integrated
control system
To 220V Line
Multiple Low Voltage Controls
Internal Screen Wiring
Blue(Neutral)
Brown
Green (Ground)
Data
Cables
Wall Switches,
Back of
Back of
RF or IR
Wall Switch
Wall Switch
Receivers,
or integrated
ILT Data Cable Connection
220V
control systems
Data Cables to switches or
MOTOR
to additional motors
DATA CABLE
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
OR
Back of
Back of
Dry Contacts
Wall Switch
Wall Switch
MOTOR
DATA CABLE
Multiple Low Voltage Controls
Internal Screen Wiring
Blue (Neutral)
Brown
Green (Ground)
Dashed wiring
by electrician
Data Cable
To 220V Line
ILT Data Cable Connection
Data Cables to switches or
to additional motors
MOTOR
DATA CABLE
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
OR
Dry Contacts
MOTOR
DATA CABLE
Please Note: 5V DC must
be connected to set limits
using the wall switch.
page 5 of 7
Internal Screen Wiring
Blue (Neutral)
Brown
Green (Ground)
Data
Cables
Wall Switches,
RF or IR
Receivers,
or integrated
control systems