- ページ 6

エアコン AirStage ASYA30GBCHのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AirStage ASYA30GBCH 8 ページ。 Indoor unit (wall mounted type)

AirStage ASYA30GBCH 取扱説明書
Water is produced from the outdoor unit:
● During Heating operation, water may be produced from the outdoor
unit due to the Automatic Defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn't operate at all:
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation different from the priority
state? (See page 2)
● Is it in standby state? (See page 2)
The operation mode cannot be changed:
● Are you trying to change to an operation different from the priority
conditions? (See page 2)
Poor Cooling (or Heating) performance:
● Did you adjust the room temperature settings (thermostat) correctly?
● Is the air filter dirty? (See page 3)
● Are the air conditioner's inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the fan speed set to low?
Set the temperature lower than the room temperature and use it:
● Temperature does not fall down well. Temperature may not fall down
depending on the room conditions. (While high humidity or the room
temperature is high.) (See page 2)
In the following situations stop operation immediately
and get in touch with authorized service personnel.
● The problem cannot be solved even when the troubleshooting checks
have been performed.
● The FILTER indicator lamp (red) is flashing very fast.
● The wired remote controller or simple remote controller indicate Er
(when connected).
● It has burning smell.
En-5

SPECIFICATIONS

MODEL
AS*A18GBCH
POWER SOURCE
AVAILABLE VOLT-
AGE RANGE
[kW]
5.6
COOLING
CAPACITY
[Btu/h]
19,100
[kW]
6.3
HEATING
CAPACITY
[Btu/h]
21,500
INPUT
[W]
32
POWER
CURRENT
[A]
0.33
SOUND PRESSURE LEVEL
HIGH
dB [A]
41
MED
dB [A]
39
LOW
dB [A]
35
DIMENSIONS & WEIGHT
HEIGHT
[mm]
WIDTH
[mm]
DEPTH
[mm]
WEIGHT
[kg]
● Acoustic Noise Information :
The maximum sound pressure level is less than 70 dB (A) for both
indoor unit and outdoor unit. According to IEC 704-1 and ISO 3744.
● This product contains fluorinated greenhouse gases.
AS*A24GBCH
AS*A30GBCH
230 V~50/60 Hz
198 to 264 V (50Hz)
198 to 253 V (60Hz)
7.1
8.0
24,200
27,300
8.0
9.0
27,300
30,700
60
91
0.52
0.69
48
52
43
45
35
35
320
998
238
15