- ページ 11

エアーコンプレッサー Draper DA50/190のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Draper DA50/190 16 ページ。 25 & 50 litre compressors

Draper DA50/190 取扱説明書
It is advisable to clean all the finned parts of
your compressor, so as to keep the cooling
system efficient and to ensure a long work
life to your machine.
OPERATIONS TO BE CARRIED OUT
EVERY 2 YEARS:
Check the non-return valve and if necessary
replace the seal.
Check intake and delivery valves on valve
plates.
Recommended Oils:
Recommended oils with ISO 100 viscosity for
compressors, in accordance with DIN51506-
VDL 100-E Standards and ISO6521:L-DAC
Specifications (suitable for room temperature
ranging from +6°C and +25°C).
AGIP
DICREA100
API
CM-8X
BP
ENERGOL CS100
CASTROL
AIRCOL PD100
ESSO
EXX OLUB H150
IP
CALATIA OIL ISO 100
MOBIL
RARUS 427
FINA
EOLAN AC 100
SHELL
COREMA OIL H100
TOTAL
CORTUSA 100
Use oils with an ISO 46/68 viscosity for a
room temperature ranging from 0°C to + 5°C
Use oils with an ISO 150 viscosity for a room
temperature ranging from + 26°C to + 45°C.
MAINTENANCE
- 10 -