- ページ 3

室内装飾品 Draper Skylight FlexShadeのPDF 説明書 インストールと操作をオンラインで閲覧またはダウンロードできます。Draper Skylight FlexShade 10 ページ。 Face mount

Skylight FlexShade

Section 1 - Prepare for Installation

Caution: Before mounting shades, verify measurements on label provided with shade, and ensure unit is installed at correct width.
Please Note: Installer is responsible for selecting mounting hardware appropriate for site conditions.
1. Look for any site conditions that could interfere with installation or operation.
2. Inspect all items prior to assembly:
a) Open cartons lengthwise and lay out all pieces.
b) Ensure that product is as ordered by checking pieces against Page 1 of this document.
3. Arrange all pieces on floor in the general manner they are to be installed and remove covers from both headboxes.
Section 1.1 - Spring Roller Removal and Re-Tensioning
1. Remove spring roller from its
headbox
. This single notch
(Fig. 1)
spring roller is pre-tensioned and
the dog is locked in its notch. To
remove, disengage pin end from
endcap.
2. Pivot roller so that spear end
can be worked out of slot in the
spear endcap. A small bushing is
included on pin end
(shown in green)
Be sure not to misplace it.
3. If tension is lost, rotate spear
clockwise a maximum
of 15 times to regain tension
Caution: Ensure arrow on spring
roller end is facing toward the floor
until ready to reassemble.
Section 1.2 -
Motor Roller Removal
1. Locate motor roller assembly
and remove from headbox.
Remove retainer clips from
motor end of roller
.
(Fig. 3)
Please Note: Be sure to keep all
retainer clips.
2. Compress spring in gudgeon by
sliding roller toward idler end of
headbox, and pivot motor end
of roller out of box.
Section 1.3 - Quality Check
1. While unit is still on floor, install both side channels to both headboxes.
Be sure both channels, fabric guides, and endcap locators are properly seated
2. Before affixing shade to ceiling, verify measurements printed on package label to preassembled shade
and the opening.
3. Check the location of building power supply to ensure motor cable will reach once properly installed.
4. Check the opening for squareness by measuring for equal diagonals.
Please Note: The unit can accommodate up to 1/ 8 "
- Face Mount
®
Figure 1
.
.
(Fig. 2)
REMOVE
RETAINER
CLIPS
MOTOR END
of variance.
(3mm)
Figure 2
Figure 3
.
(Fig. 4)
page 3 of 10
GUDGEON END
Flange
Locator
Fabric
Guide
Figure 4
Glide
Strip