- ページ 6
エアコン AirStage AUUA12RLAVのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AirStage AUUA12RLAV 8 ページ。 Indoor unit (wall mounted type)
The following conditions may not be breakdowns so check again.
Symptom
Doesn't operate at all:
The operation mode cannot be
changed:
Poor Cooling (or Heating)
performance:
Set the temperature lower than
the room temperature and use it:
In following situations stop operation immediately and get in touch with authorized service personnel.
●
The problem cannot be solved even when the troubleshooting checks have been performed.
●
The OPERATION indicator lamp (green) is fl ashing very fast.
●
The wired remote controller or simple remote controller indicate Er (when connected).
●
It has burning smell.
SPECIFICATIONS
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
HEATING CAPACITY
SOUND PRESSURE LEVEL
HIGH
MED
LOW
DIMENSIONS & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
●
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor unit.
En-5
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main power switch set to the OFF position?
Are you trying to engage in an operation different from the priority state?
Is it in standby state?
Are you trying to change to an operation different from the priority conditions?
Did you adjust the room temperature settings (thermostat) correctly?
Is the air fi lter dirty?
Are the air conditioner's inlet port or outlet port blocked?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sunlight to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are
there too many people in the room?
Is the fan speed set to low?
Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.)
ASUA7RLAV
[Btu/h (kW)]
[Btu/h (kW)]
dB [A]
dB [A]
dB [A]
[in. (mm)]
[in. (mm)]
[in. (mm)]
[lbs. (kg)]
According IEC 704-1 and ISO 3744.
Items to check
ASUA9RLAV
7,500 (2.2)
9,500 (2.8)
9,500 (2.8)
10,900 (3.2)
35
36
33
33
31
31
ASUA12RLAV
208/230 V ~ 60 Hz
187 to 253 V
12,000 (3.5)
13,500 (4.0)
39
35
31
10-13/16 (275)
31-3/32 (790)
8-15/32 (215)
20 (9)
See page
—
—
—
2
2
2
—
3
—
—
—
—
—
3
ASUA14RLAV
14,000 (4.1)
15,600 (4.6)
44
37
32