- ページ 7

リモコン AirStage UTY-LNH seriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AirStage UTY-LNH series 15 ページ。 Air conditioner remote controller wireless type
AirStage UTY-LNH series にも: 取扱説明書 (16 ページ)

To Stop Operation
Press the "START/STOP" button.
The OPERATION Indicator Lamp (green) will go out.
About AUTO CHANGEOVER Operation
AUTO:
● When AUTO CHANGEOVER operation fi rst selected, the fan will ope-rate
at very low speed for about 1 minute, during which time the unit detects the
room conditions and selects the proper operating mode.
Room temperature is higher than the defi ned temperature in temperature
setting → Cooling mode or Dry mode
Room temperature is close to the defi ned temperature in temperature
setting → Determined by outdoor temperature
Room temperature is lower than the defi ned temperature in temperature
setting → Heating mode
● When the air conditioner has adjusted your room's temperature to near the
temperature setting, it will begin monitor operation. In the monitor operation
mode, the fan will operate at low speed. If the room temperature subsequently
changes, the air conditioner will once again select the appropriate operation
(Heating, Cooling) to adjust the temperature to the value set in the indoor
unit.
(The monitor operation range is ±2 °C relative to the temperature
setting.)
● If the mode automatically selected by the unit is not what you wish, select
1 of the mode operation (HEAT, COOL, DRY, FAN).
About Mode Operation
Heating: ● Use to warm your room.
● When Heating mode is selected, the air conditioner will operate at very low
fan speed for about 3 to 5 minutes, after which it will switch to the selected
fan setting. This period of time is provided to allow the indoor unit to warm
up before beginning full operation.
● When the room temperature is very low, frost may form on the outside unit,
and its performance may be reduced. In order to remove such frost, the unit
will automatically enter the defrost cycle from time to time. During Automatic
Defrosting operation, the OPERATION Indicator Lamp (green) will fl ash, and
the heat operation will be interrupted.
● After the start of heating operation, it takes some time before the room gets
warmer.
Cooling: ● Use to cool your room.
● Use for gently cooling while dehumidifying your room.
Dry:
● You cannot heat the room during Dry mode.
● During Dry mode, the unit will operate at low speed; in order to adjust room
humidity, the indoor unit's fan may stop from time to time. Also, the fan may
operate at very low speed when adjusting room humidity.
● The fan speed cannot be changed manually when Dry mode has been
selected.
● Use to circulate the air throughout your room.
Fan:
Cooling or Dry
Defi ned temper-
ature in tem-
Determined by out-
perature setting
door temperature
Heating
During Heating mode:
Set the temperature to a temperature setting
that is higher than the current room tempera-
ture. The Heating mode will not operate if
the preset temperature is set lower than the
actual room temperature.
During Cooling/Dry mode:
Set the temperature to a temperature setting
that is lower than the current room tempera-
ture. The Cooling and Dry modes will not op-
erate if the preset temperature is set higher
than the actual room temperature (in Cooling
mode, the fan alone will operate).
During Fan mode:
You can not use the unit to heat and cool
your room.
En-6