5.1 Data logger
The battery powered digital gauge disposes of an integrated data
logger. The measuring values stored away in the device can be
selected above the communication interface by means of
software BD|LOG (included in delivery).
5.2 PC - connection
Connect
device
with a computer as follows:
-
unscrew the protective screwing of the communication
interface with a suitable slit screwdriver.
-
connect the handle plug of the connecting cable (included
in delivery) with the interface socket of the device. Con-
nect the side with the USB plug with a free USB connec-
tion on the computer.
-
install the COM driver and data logger software BD|LOG,
receive available on CD (included in delivery).
-
after the use, disconnect the connection and lock the
protection screwing again properly.
6. Initial start-up
remove the insulation foil before first
WARNING! Before start-up, the user has to check for
proper installation and for any visible defects.
WARNING! The device can be started and operated by
authorized personnel only, who have read and understood
the operating manual!!
WARNING! The device has to be used within the technical
specifications, only (compare the data in the data sheet)!
7. Placing out of service
WARNING! When dismantling the device, it must always be
done in the depressurized and currentless condition! Check
also if the medium has to be drained off before dismantling!
WARNING! Depending on the medium, it may cause
danger for the user. Comply therefore with adequate
precautions for purification.
8. Operation
8.1 Operating and display elements
barograph
timer / battery
time
display
pressure value
right button
left button
menu - button
temperature
Fig. 4 Display and operating foil
The display of the measuring value as well as configuring the
single parameters occurs menu-steered about a LC display
capable of graphic arts. The single functions are regulated on the
basis of three-front-sided arranged push buttons.
The menu system is closed, thereby one can "browse" forward
as well as backward by the single setting menus to reach to the
desired setting point.
8.2 Structure of the menu system
7.3 Menu list
Switch on
Menu 1/9
on / off
Menu 2/9
date / time / info
Menu 3/9
Units
Menu 4/9
Min / Max Values
introduction.
Menu 5/9
Configuration 1
Menu 6/9
Configuration 2
Menu 7/9
Backlight
Menu 8/9
Data Logger
Menu 9/9
Sensor Data
Error
- Left Button:
- Right Button: if is a functional button and can be configured in the menu 6. Light-, Zero-, Reset- or Max- function can
- Menu-Button: by pressure of this button "menu" you reach in the operating mode; moreover, she serves for the choice
To the configuration of the single menu points the desired menu point is to be put with the help of the left button "<<" or right
button ">>". Confirm this afterwards with the menu button "Edit" the menu point is marked and the configuration can begin.
To store an opposed value the menu button "Next" must be also pressed. To leave the menu press the menu button so often
to the mark of the single menu point and choose with the left button "<<" or right button ">>" the menu 1 and press the menu
button once more "Exit". The operating mode will also leave after approx. 1 min automatically.
Changes become first after activity of the menu button "Next" and after abandonment of the menu point effective. With
the abandonment of the whole menu system the opposed parameters are checked once again in dependence to each
other and concerning the characteristics of the device. With the configuration of the unity a conversion of the measuring
area occurs in the new unity only after abandonment of the menu system. According to pressure area not all units can be
also used if necessary.
9. Maintenance
In principle, this device is maintenance-free. If desired, the
housing of the device can be cleaned when switched of using a
damp cloth and non-aggressive cleaning solutions.
With certain media, however, the diaphragm may be polluted or
coated with deposit. It is recommended to define corresponding
service intervals for control. After placing the device out of
service correctly, the diaphragm can usually be cleaned carefully
with a non-aggressive cleaning solution and a soft brush or
sponge. If the diaphragm is calcified, it is recommended to send
the device to BD SENSORS for decalcification. Please read
therefore the chapter "Repair" below.
!
A false cleaning of the device can cause an irreparable
damage on the diaphragm. Therefore never use pointed ob-
jects or pressured air for cleaning the diaphragm.
11. Service / Repair
We recommend that the instrument is regularly recalibrated by
BD SENSORS, with timeintervals of approx. 12 months.
Before you return, the device has to be cleaned carefully and
packed shatter-proofed. You have to enclose a notice of return
with detailed defect description when sending the device. If your
device came in contact with harmful substances, a declaration of
decontamination is additionally required. Appropriate forms can
be downloaded from our homepage www.bdsensors.com.
Should you dispatch a device without a declaration of
decontamination and if there are any doubts in our service
department regarding the used medium, repair will not be started
until an acceptable declaration is sent.
The device can be switched on with every button (left button, menu button, right button).
By push the menu button the operating mode will be selected / left / ("Menu" / "Exit").
Setting of topical time and the topical date. Software version will be showed.
Setting of the pressure unit
adjustable units: [bar], [mbar], [PSI], [inHg], [cmHg], [mmHg], [hPa], [kPa], [MPa], [mmH2O], [mH2O], [kg/cm
or [user] (the user-defined unit can be programmed only by means of the software BD|LOG), a conversation of
all pressure related parameters is carried out automatically
Setting of decimal places
adjustable decimal place: standard [Std], [+1], [+2]
Setting of the temperature unit
the unity is not adjustable. Factory setting [°C]
Displaying of Min / Max Values
P
- Minimum pressure display: The minimum pressure applied during measuring is shown in the display.
min
P
- Maximum pressure display: The maximum pressure applied during measuring is shown in the display.
max
T
- Maximum pressure display: The minimum temperature during measuring is shown in the display.
min
T
- Maximum temperature display: The maximum pressure applied during measuring is shown in the display.
max
Possible options: reset value [Reset ?]
(Resetting of a value: select the menu point with "Edit" → button ">>" operate. There appears the question "Reset?" → once more
operate the button ">>". It seems "Sure?" additional confirmation whether the value should be put back → repeated confirming with the
button ">>" takes over topically adjoining pressure as a minimum value.)
Language:
Setting of user languages German [DE] or English [EN]
Measuring rate: here it is put how often the measurement is carried out and is indicated.
Possible settings are: a measurement per second [1/sec]
or two measurements per second [2/sec]
Auto Off Time:
Setting of the automatic switch off in minutes. The automatic switch off is able in steps from
[1 min], [2 min], [3 min], [4 min] or [5 min]; 30 seconds before switching off the timer is
activated and indicated in the display.
By the option [Off] the device can be deactivated. After deactivation, the precision digital
gauge is in the continuous operation.
Button settings: left button / right button
Left Button:
function configurations: [Min], [Light], [Zero], [Reset]
Right Button:
function configurations: [Max], [Light], [Zero], [Reset]
Function descriptions:
- [Min] / [Max]
- [Light]
- [Zero]
- [Reset]
Damping:
the damping can be put in 1 second steps between [1 sec] and [10 sec] or be
deactivated by option [Off]
Backlight settings of display
On Time:
the backlight duration can be put in 1 second steps between [1 sec] and [10 sec] or be
deactivated by option [Off]
Brightness:
the brightness can be put into 5% of steps between [0%] and [100%]
Data Logger configuration
Data Logger:
the following settings are possible: linearly [Linear] (value admission to the counter level 8500
is reached), cyclically ( [Loop] (after the value is reached in 8500, the data logger automatically
begins the values once more to grasp and, besides, headlines the old values) or [Off]
(in the display appears
Interval:
Intervals to the memory of the measuring values (pressure / temperature) second [1-99 sec],
minute [1-99 min], hour [1-99 hour] or day [1-99 days]
Time:
Measuring value admission: in which time the measuring value admission should occur (is
only efficiently for the setting "daily").
Counter:
Number of the grasped measuring values is indicated. Maximum value: 8500
(Put back counter reading: menu point with "Edit" select → button "Next" four times operate → button ">>" operate. There appears the
question "Reset?" → once more operate the button ">>". It seems "Sure?" additional confirmation whether the value should be reset →
repeated confirming with the button ">>" reset the grasped measuring values. Display announcement "Counter: 0/8500")
[SN:]
the standard number is indicated
[Lower]
Measuring area beginning
Values are put by factory and are not adjustable.
Display "No Sensor": display and pressure sensor module are separated.
if is a functional button and can be configured in the menu 6. Light-, Zero-, Reset- or Min- function can be
assigned to the button. The configured function is active in the display mode. Hold the button during
approx. 2 seconds to activate the function. In the operating mode you move in the menu system back-
ward "<<" or you reduce the set value.
be assigned to the button. . Hold the button during approx. 2 seconds to activate the function. In the op-
erating mode you move in the menu system forward ">>" or you raise the set value.
of the single menu points "Edit" or in the confirmation the opposed worth "Next".
minimum / maximum pressure value will be showed
the display backlight is activated
the zero point is automatically put, in the display appears
the opposed zero is put back,
goes out
if the data logger is activated and goes out if the data logger is off)
[Upper]
Measuring area end
[Date]
Production date
If the device came in contact with hazardous sub-
stances, certain precautions have to be complied with
for purification!
12. Disposal
The device must be disposed according to the
European Directives 2002/96/EG and 2003/108/EG
(on waste electrical and electronic equipment)
Waste of electrical and electronic equipment may
not be disposed by domestic refuse!
WARNING! Depending on the measuring medium, deposit
on the device may cause danger for the user and the
environment. Comply with adequate precautions for
purification and dispose of it properly.
13. Warranty conditions
The warranty conditions are subject to the legal warranty period
of 24 months from the date of delivery. In case of improper use,
modifications of or damages to the device, we do not accept
warranty claims. Damaged diaphragms will also not be accepted.
Furthermore, defects due to normal wear are not subject to
warranty services.
14. Declaration of conformity / CE
The delivered device fulfils all legal requirements. The applied
directives, harmonised standards and documents are listed in the
EC declaration of conformity, which is available online at:
http://www.bdsensors.com/products/ download/certificates.
Additionally, the operational safety is confirmed by the CE sign
on the manufacturing label.