- ページ 2
洗濯機 Electrolux 427 seriesのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Electrolux 427 series 24 ページ。
2
Diagnostic Mode Tests
MODE
TEST NAME
NUMBER
Lights, Buttons
PODS
(no test for 400 series)
(select models only)
Wash compartment
Bleach compartment
Softener compartment
Stain compartment
Wash compartment
Door unlock
Heater & motor
Recirculation Pump
(no test on 400 series )
Concentrate wash pump
(no test on 400 and 500
series)
Drain pump & spin
All valves on
Error history
* Note for diagnostic mode only: The door is locked in the spin test step, however it can unlock without delay in another test step or on
exiting diagnostic mode, when opening the door the drum can have energy as it spins down.
COMPONENTS UNDER TEST
• LED indicators
• LCD screen
• Button response
compartment
• Door lock
®
• PODS
®
• Door lock
• Hot valve
• Door lock
• Bleach valve
• Door lock
• Prewash valve
• Bleach valve
• Door lock
• Prewash valve
• Door lock
• Cold valve
• Drum light
• Pressure sensor
• Cold valve
• Motor
• Heater
• NTC
• Door lock
• Drum light
• Recirculation pump
• Pressure sensor
• Cold valve
• Motor
• Door lock
• Drum light
• Concentrate wash pump
• Door lock
• Drum light
• Drain pump
• Motor
• Door lock
• Door lock
• All valves
• The last 3 errors in memory
TEST CONDITIONS
Valve stays on until water level reaches
valve
20 liters. Then door remains locked for
5 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Drum light turns on when door is open.
Motor moves after machine fills with
60 mm of water. Heater heats
until temperature reaches 70º C.
Max. duration of test is 8 minutes.
Need power meter to check heater
functionality.
Motor moves after machine fills with
140 mm of water. Recirculation pump
turns on. Max. duration of the test is 8
minutes.
Concentrate wash pump turns on for
max. 5 minutes. Need power meter
to check concentrate wash pump
functionality.
Drain pump turns on until empty, then
motor starts spinning at max. rpm for 30
seconds. Then door remains locked for
6 minutes.*
Valve stays on until water level reaches
140 mm. Then door remains locked for
5 minutes.*
Errors are displayed in order of history
(most recent first).
Note: Pressing temp + select (set)
buttons together clears error history.
DISPLAYED FEEDBACK
Number of key pressed.
Note: This number may not
necessarily correspond to key
number on table on page 1.
Water level
Water level
Water level
Water level
Water level
Water level
NTC reading
Display
Display
Display (drum speed/10)
water level
precedes the 2 character
alarm code, alternating through
the alarms