バーナー Carlin 102CRDのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Carlin 102CRD 20 ページ。 Advanced oil burners 0.5 to 4.5 gph

- 1. Table of Contents
- 2. PLEASE Read this First
- 3. Codes and Standards
- 4. EZ-66 & 102 Oil Nozzle Selections
- 5. Prepare Site • Assemble Burner • Mount Burner
- 6. Prepare Burner
- 7. Adjustment and Verification
- 8. Annual Start-Up and Service
- 9. Repair Parts
- 10. Maintenance Procedures
- 11. User Care and Maintenance
Ratings
Input:
99FRD, EZ-66 .........................................0.50 to 3.00 GPH
102CRD (2
/
" air cone) ........................ 2.00 to 3.50 GPH
5
8
102CRD (3" air cone) ............................ 3.00 to 4.50 GPH
Fuels:
U.S. ................................................No. 1 or No. 2 Fuel oil
Canada .................... No. 1 Stove oil or No. 2 Heating oil
Fuel unit:
...............................................................................Suntec
........................................ 100 to 150
Electrical:
Power ..............................................120V/60 Hz/1-Phase
Motor................................Carlin PSC, 1/6 HP, 3450 RPM
Current
99FRD, EZ-66 ..............................Approx. 5.5 amps
102CRD .......................................Approx. 6.0 amps
Ignition:
................. Carlin Model 41000 electronic - 19,000 volts
Control:
........................... U.L. Group I or II primary safety control
Agencies:
............................................... UL Listed (US and Canada)
Installer/servicer - Except where specifically stated other-
wise, this manual must be used only by a qualified service
technician. Failure to comply with this or other requirements
in this manual could result in severe personal injury, death or
substantial property damage.
User - Refer only to User care and maintenance on back page
for information regarding operation of this burner. The burner
Instruction Manual is intended only for your service technician.
The burner and heat exchanger must be inspected and started
at least annually by your service technician.
Advanced Oil Burners
Instruction Manual
Contents
PLEASE read this first .......................................................2
Codes and Standards ........................................................2
1. 99, EZ-66 & 102 Oil Nozzle Selections ........................3
3. Prepare Burner ............................................................9
4. Adjustment and Verification .......................................14
nozzle pressure
psig
5. Annual Start-up and Service ......................................15
6. Repair Parts ...............................................................16
7. Maintenance Procedures ...........................................18
User care and maintenance ...............................Rear cover
©
Copyright 2015 - Carlin Combustion Technology, Inc.
Carlin Combustion Technology, Inc.
126 Bailey Road
Ph 203-680-9401
T
ech support
99FRD
Models
102CRD
EZ-66
0.5 to 4.5 GPH
carlincombustion.com
800-989-2275
North Haven, CT 06473
Fx 203-680-9403