配管製品 Advanced Global Technology 525972のPDF インストール手順をオンラインで閲覧またはダウンロードできます。Advanced Global Technology 525972 2 ページ。 Single handle lavatory faucet
SINGLE HANDLE
LAVATORY FAUCET
Models 528224, 527747, 528109
529081, 529115, 529214, 527440
525998, 525980, 525972
Your new Design House faucet will give you years of trouble free performance. Thank you for
choosing our product for your home. Please read all of these instructions carefully before
installing your new faucet.
Helpful tools to install this faucet:
basin wrench
Teflon tape
(2) crescent wrenches
IMPORTANT POINTS
When installing your new faucet, hand tighten the connector nuts, then use one wrench to
anchor the fitting and a second wrench to tighten the nut one additional turn. Connections that are
too tight will reduce the integrity of the system.
Wrap all threaded connections (except aerator thread in spout) with Teflon tape available from
your local hardware or plumbing supply store. Always wrap in a counter-clockwise direction.
ALWAYS protect your eyes with safety glasses.
TROUBLE SHOOTING
Problem: Faucet leaks from under handle.
Cause: Adjusting ring or cap nut is loose.
Action:
1. Remove handle by loosening set screw with
allen wrench.
2. Tighten the adjusting ring by turning it
clockwise with a small screwdriver. Move ball
stem to the on position and continually tighten
the adjusting ring until the leak stops draining
out from around the ball stem.
3. If the leak does not stop, loosen the adjusting
ring and tighten the entire cap assembly by
turning it clockwise. Retighten the adjusting ring
as before.
4. Replace the handle and tighten the set screw.
Many of these parts come preassembled.
This exploded diagram is to assist in
trouble shooting.
HANDLE
ADJUSTING RING
CAP NUT
SET
SCREW
HOT/COLD
INDICATOR
CAM ASSEMBLY
COVER
BALL ASSEMBLY
SEAT
SPRING
SPOUT
FAUCET
BODY
AERATOR
NOSE
RISER (2)
COUPLING
NUT (2)
silicon sealer
flashlight
faucet supply tubes
SAFETY TIPS
Problem: Water does not completely shut off.
Cause: Rubber valve seat is dirty or worn or
adjusting ring or cap has loosened.
Action:
1. Turn off the water under the sink.
2. Remove handle by removing hot/cold indicator
and loosening set screw with allen wrench.
3. Unscrew the cap nut. Remove the cam
assembly and ball assembly.
4. Inspect the two rubber valve seats for debris or
damage. Replace if necessary.
5. Push the rubber seats and springs back in with
smaller ends up. Take care when replacing the
metal ball to align the metal peg on the side of the
body with the oblong slot on the ball.
6. Reassemble the faucet taking care to fit the
small alignment tab on the cam into the slot. Make
sure cap nut is tight and fits flush with faucet body
before reattaching handle.
7. Retighten the adjusting ring. Replace the handle
and tighten the set screw.
8. Turn on the water under the sink.
Problem: Faucet leaks around aerator or has an
improper flow pattern.
Cause: Aerator incorrectly fitted or dirty.
Action:
1. Unscrew the aerator. Make sure all internal
parts are laying flat.
2. If there is debris, gently flush all parts inside.
3. Reinstall aerator.
POP-UP INSTALLATION
EXPLODED PARTS
LIFT ROD
DRAIN STOPPER
FLANGE
MACK WASHER
PLASTIC FRICTION
WASHER
LOCKNUT
THREADED
ROD
POP-UP DRAIN
BODY
COPPER
WATER INLET
GASKET
BUSHING
PIVOT ROD
& BALL
BUSHING
WASHER
PIVOT ROD
OPENING
TAIL PIECE
LOCK NUT
1. Shut off hot and cold water supplies under sink. Plug sink drain with cloth to avoid losing small
parts. Remove old faucet.
2. Screw both threaded rods into
the threaded receptacles located
under faucet body.
3. FIT GASKET TO BOTTOM OF
FAUCET BODY BEFORE
INSTALLING FAUCET ON SINK.
Install faucet with gasket through
sink holes. From under the sink
slide metal washers onto threaded
rods with the open slots around the
copper water inlets. Then screw
the locknuts onto the threaded rods.
Make sure faucet is in the correct
position and tighten locknuts.
Your new Design House faucet is designed to give you years of trouble free performance. Keep it
looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh
chemicals that will dull the finish and void your warranty.
Brass finishes are polished, then protected with a lacquer coating to help prevent tarnishing. Clean
these surfaces only with a damp, soft cloth.
Under the Safe Drinking Water Act, the U.S. Environmental Protection Agency restricts the
amount of lead used in brass and solder. Your new faucet is made in strict compliance with all
government standards. The materials used in the manufacture of this faucet are of industry
standard quality and are similar to other plumbing products having brass fittings.
To reduce the amount of lead in your drinking water, allow the water to run for a moment before
filling your glass and remember to always use cold water for drinking purposes.
POP-UP (OPTIONAL) INSTALLATION PROCEDURE
1. Remove stopper and unscrew
flange from pop-up assembly.
2. Insert pop-up drain body with mack
washer, plastic friction washer (not
included with plastic pop-ups) and
locknut through bottom of sink drain.
3. Apply silicone sealer to the
underside of the flange and screw it
to the top of the the pop-up drain
body. Unscrew the tail piece. Add
Teflon tape to the tail piece threads
and reattach.
4
7. Insert pivot rod into the first spring
THUMB
SCREW
clip hole. Guide the pivot rod through
one of the holes in the rod strap and
secure in the second spring clip hole.
ROD
STRAP
8. Adjust the height of the lift rod by
loosening the thumb screw, positioning
the lift rod, and tightly resetting the
thumb screw.
SPRING
CLIP
RETAINING
NUT
INSTALLATION PROCEDURE
4. WRAP THREADED
SECTION OF THE COPPER
LINES WITH TEFLON TAPE
BEFORE CONNECTING
WATER SUPPLY LINES.
Connect copper water inlet to
hot and cold water lines using
coupling nuts and nose risers
if necessary. Use care to not
bend or kink the copper water
inlets. Bent or kinked inlets will
void the warranty.
2,3
4
MAINTENANCE
CONSUMER PROTECTION WARNING
1
4. Tighten locknut, making sure the
5
6
NON-
mack washer fits into drain hole. Insert
REMOVABLE
tail piece into waste drain tube and
tighten slipnut.
REMOVABLE
5. Insert stopper into the drain opening
in a removable or non-removable
position. Place pivot bushing inside of
pivot rod opening. Place pivot rod and
ball, and second bushing into opening.
Secure with retaining nut. Do not over
tighten.
6. Insert lift rod through lift rod strap.
Tighten with thumb screw.
5. Remove aerator and turn on
water. Allow both hot and cold
water to run for at least one
minute to flush system of any
debris. Turn off and replace
aerator.
6. Check for leaks. Correct by
slightly tightening connections. IF
LEAKS PERSIST, SEE TROUBLE
SHOOTING.
5
2
3
SILICONE
SEALER
TEFLON
TAPE
7,8