Fault
The motor does not start after
pressing the ON/OFF switch
or stops during operation.
The automatic circuit breaker
in the electrical distribution
board trips.
The magnetic clamp does not
function.
The lubrication system does
not function.
NOTE
If you cannot resolve the problem with the steps described above, please contact cus-
tomer service.
MABasic 200, 400, 450, 850

Troubleshooting

Possible cause
Plug not inserted into socket.
Automatic circuit breaker
tripped.
The magnetic clamp is not
switched on.
Too many appliances con-
nected to the same power
circuit.
The machine is defective.
Magnet not switched on.
The surface is not magnetic.
No lubricant available.
Lubricant tap closed.
Connecting nipple clogged.
Troubleshooting
Remedy
Insert plug.
Switch on the automatic circuit
breaker again.
Switch on the magnetic clamp.
Reduce the number of appli-
ances on the power circuit.
Contact customer service.
Switch on the magnet.
Use a suitable base.
Top up the lubricant.
Open the lubricant tap.
Clean the tank and nipple.