Drazice OKCV 180 操作および設置マニュアル
Type
Capacity
Max operating overpressure in the tank
Maximum operating overpressure in the exchanger*
Electric connection
Power input
El.protection
Max temperature of HSW
Recommended HSW temperature
Height of the heater
Diameter of the heater
Max weight of the heater without heater
Time of el.heating from 10°C to 60°C
Heat losses/energy efficiency class
Type
Exchanger heat surface
Rated thermal output at heating water
temperature of 80°C and flow 720 l/h
Time of heating by exchanger from 10°C to 60°C min
Rated thermal output at heating water
temperature of 80°C and flow 310 l/h
Time of heating by exchanger from 10°C to 60°C min
*The OKCEV series heaters do not have a heat exchanger.
OKCEV 100
l
100
MPa
MPa
-
V
W
°C
°C
mm
881
mm
524
kg
41
hod
3
kWh/24h
0,88/C
2
m
-
W
-
-
W
-
-
10

OKCV 125

OKCV 160
OKCEV 125
OKCEV 160
125
152
0,6
1 PE-N 230V/50Hz
2000
IP 44
80
60
1046
1235
524
524
59/47
68/56
3,8
5
1,09/C
1,39/C
OKCV 125
OKCV 160
0,7
0,7
16800
16800
26
35
10260
10260
43
53
OKCV 180
OKCV 200
OKCEV 180
OKCEV 200
180
200
0,4
2200
1187
1287
584
584
80/69
84/73
5
5,5
1,39/C
1,4/B
OKCV 180
OKCV 200
0,75
0,75
18000
18000
38
43
11000
11000
63
72