2.6 FIRST COMMISSIONING
After connecting the heater to the water supply, the hot water heating system, the electric
network, and after testing its safety valve (based on the valve manual attached), the heater
may be put into operation. Before opening the power supply, the tank must be filled
with water. The process of first heating must be executed by licensed professional who has to
check it. Both the hot water outlet pipe and safety armature parts may be hot.
During the heating process the pressurised connection water that increases its volume
due to heating must drip off the safety valve. In non-pressurised connection water drips off
the overflow combination faucet. When heating is finished, the set temperature and the
actual temperature of consumed water must be more-or-less the same. After connecting the
heater to the water main and electrical power system, and after checking the safety valve
(following the instructions attached to the valve), the heater can be put into operation.
Procedure of putting the heater into operation:
1. Check both water and electric installation; for combined heaters, check the installation to a hot water
heating system. Check proper placement of operating and safety thermostat sensors. The sensors
must be inserted all the way in; first the operating and then the safety thermostat.
2. Open the hot water valve on the combination faucet.
3. Open the cold water inlet valve to the heater.
4. As soon as the water starts running through the hot water valve, the heater is filled and the valve
can be closed.
5. In case of leakage (of flange lid), we recommend that the flange lid bolts are fastened.
6. Screw down the electric installation guard.
7. When hot sanitary water is heated by electric energy, switch on the power supply (the valve
on the heating water inlet to the heating insert must be closed in combined heaters).
8. When sanitary water is heated with electric energy from the hot water heating system, turn off
electricity an open the valves on the heating water inlet and outlet, possibly de-aerate the exchanger.
9. When commencing operation, flush the heater until the cloudiness in the water is gone.
10. Make sure to fill in properly the warranty certificate.
2.7 PUTTING OUT OF SERVICE, DISCHARGE
If the hot water heater is put out of service for a longer time, or if it is not going to be used
it has to be drained and disconnected from the electric supply network on all poles. The switch
for the supply lead or the fuse cut-outs have to be shut off.
At places with permanent risk of frost the hot water heater must be drained before the cold
season starts if the appliance remains out of service for several days and if the power supply
is disconnected.
Drainage of utility water shall be performed after closing the shut-off valve in the cold water
supply piping (through the discharge valve for safety valve combination), and with
simultaneous opening of all hot water valves of connected fittings. Hot water may outflow
during the drainage! If there is a risk of frost it has to be considered that not only the water
in the hot water heater and in the hot water piping may get frozen but also the water in the
- 14 -