9.
PUTTING THE HEATER INTO OPERATION
After connecting the heater to the water main, hot water heating system and power supply, and after checking the safety
valve (following the instructions attached to the valve), the heater can be put into operation.
Procedure:
a)
Check both water and electric installation; for combined heaters, check the installation to a hot water heating
system. Check proper placement of thermostat sensors; The sensors in the thermowell have to be inserted all the
way.
b)
Open the hot water valve on the combination faucet
c)
Open the cold water inlet valve to the heater.
d)
As soon as the water starts running through the hot water valve, the heater is filled and the valve closes.
e)
In case of a leakage (flange lid), we recommend fastening the flange lid bolts.
f)
Fasten the electric installation cover.
g)
When heating service water with electric energy from the hot water heating system, open the heating water inlet
and outlet valves, possibly de-aerate the heat exchanger.
h)
When commencing operation, flush the heater until the cloudiness in the water is gone.
i)
Make sure to fill in properly the warranty certificate.
10.
HEATER CLEANING AND ANODE ROD EXCHANGE
Repetitive water heating causes limestone sediment on both the tank walls and chiefly the flange lid.
The sedimentation depends on the hardness of water heated, its temperature, and amount of hot water consumed.
We recommend checking and cleaning the tank from scale and eventual replacement of the anode rod
after two years of operation. The anode life is theoretically calculated for two years of operation; however, it changes
with water hardness and chemical composition in the place of use. Based on such an inspection, the next term of anode
rod exchange may be determined. Have the company in charge of service affairs clean and exchange the anode. When
draining water from the heater, the combination faucet valve for hot water must be open, preventing occurrence of
under-pressure in the heater tank which would stop the water from draining.
11.
IMPORTANT NOTICES
Check and exchange the Mg anode regularly.
No stop valves can be put between the heater and the safety valve.
If the overpressure in the eater main exceeds 0.6 MPa, a reduction valve must be
mounted before the safety valve.
All hot water outputs must have a combination faucet.
Before filling the heater with water for the first time, it is recommended to fasten the
flange connection nuts of the tank.
It is not allowed to handle the thermostat, aside from temperature resetting with a
control button.
All electric installation handling, adjustment and replacement of the regulation
elements shall only be performed by an authorised service company.
Disposal of packaging material and functionless product
A service fee for providing return and recovery of packaging material has been paid for the packaging in which the
water heater was delivered was paid pursuant to Act No. 477/2001 Coll., as amended, at EKO-KOM a.s. The client
number of the company is F06020274. Take the water boiler packages to a waste disposal place determined by the
town. When the operation terminates, disassemble and transport the discarded and unserviceable heater to a waste
recycling centre (collecting yard), or contact the manufacturer.