STERILIZING SMALL PARTS
1. Add 2 oz / 60 ml of DISTILLED water directly into the Warming Chamber. Do not
2.
Lift-Out Basket.
3. Place the Lift-Out Basket with small parts into the Warming Chamber.
4. Place the Adapter Ring on top of the Warming Chamber.
5. Place the Sterilizing Lid on top of the Adapter Ring.
6. Plug in the power cord and press the Power Button. The Indicator Light will turn on,
indicating the sterilizing cycle has begun.
7.
8. Allow the unit to cool for at least 10 minutes before removing the Sterilizing Lid,
Adapter Ring, and Lift-Out Basket.
NOTE: Be sure to observe the 10-minute cooling time as warmer parts and
sterilized parts will be hot. Always remove the Sterilizing Lid carefully by the
handle. Take care when removing the Sterilizing Lid as there may be some
residual steam—keep hands and face away. Allow the steam to clear before
reaching into the unit. Always retrieve the sterilized parts by removing the
Lift-Out Basket.