- ページ 8
試験装置 ANCEL AJ400のPDF マニュアルをオンラインで閲覧またはダウンロードできます。ANCEL AJ400 13 ページ。 Gdi injector cleaner & tester
ANCEL
3.2 Installation of side-supply injectors
1)
Choose proper couplers for side-supply injectors and proper O-rings, and mount them together.
2)
Before fixing, best to apply a little lubricating fuel on the O-ring.
3)
If some cylinder is not used, need to install the plug.
IV. Operating Procedures
4.1 Preparation
1)
Remove the injector from the motorcycle engine to check the o-rings inside for damage. If it is be damaged
need to replace it. Put the outside of injector in gasoline or detergent, and wipe them with soft cloth after
cleaning the outside fuel sludge carefully.
2)
Check the test liquid level to be sure there are enough test liquid inside tank. Pouring test liquid from the port
at the top left side of the unit and watch the liquid level in the fuel level viewer. In most cases, filled the liquid
up to 1/2 of the tank capacity.
3)
Turn on the power switch on the right of the
4)
Pour ultrasonic detergent into the ultrasonic cleaning basin so that the needle valve of the injector is covered by
the detergent.
5)
Connect the injectors with the right couplers.
• The main unit of the device uses test solution for uniformity / sprayability test, leakage test, injecting flow test and
auto. test. The ultrasonic cleaner uses the cleaning agent. Test solution and cleaning agent are not included in the
standard configuration and can be purchased separately.
4.2 Cleaning & testing sequences
Recommended to carry out the complete cleaning and testing procedures as the following order.
Ultrasonic cleaning;
Uniformity / Sprayability test;
Leakage test;
Injecting flow test;
Working modes test.
4.3 Procedure after work operation
1)
Drain test solution to a fuel container.
2)
Switch off the power switch and unplug the power plug.
Use a fuel header to suck all cleaning agent in the ultrasonic cleaning pool, and wipe the pool with a soft dry
3)
cloth.
4)
Wipe the table top of the machine with a soft dry cloth.
5)
To avoid volatilization, all the test solution in the fuel tank should be discharged. If it can be used again, store it
in a safe place. If it is dirty and cannot be used any more, dispose it according to relevant regulations.
(Installation of side-supply injectors)
Cabinet.
5