- ページ 8
セキュリティセンサー CARLO GAVAZZI LDP1PA2DU24のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。CARLO GAVAZZI LDP1PA2DU24 20 ページ。 Loop detector
3. Wiring diagrams
LDP plug in version required to be plugged into a socket ZPD11A which is sold separately.
Single loop (LDP1) plug configuration
Relay 2
5
4
Relay 1
3
2
Supply
Dual loop (LDP2) plug configuration
Relay 2
5
4
Relay 1
3
2
1
Supply
8
Rev.00 - 09.2018 | LDP1/LDP2 Single and Dual Loop Detector | © 2018 | CARLO GAVAZZI Industri
Loop
6
7
8
9
10
1
11
Loop 1
6
7
8
Loop 2
9
10
11
1
Supply
2
Supply
3
Relay 1 (N.O.)
4
Relay 1 (COM)
5
Relay 2 (N.O.)
6
Relay 2 (COM)
7
Loop
8
Loop
9
Earth
10
Relay 2 (N.C.)
11
Relay 1 (N.C.)
Earth pin must be connected to earth
Do not wipe grease off pins
1
Supply
2
Supply
3
Relay 1 (N.O.)
4
Relay 1 (COM)
5
Relay 2 (N.O.)
6
Relay 2 (COM)
7
Loop 1
8
Loop 1, 2, Earth
9
Loop 2
10
Relay 2 (N.C.)
11
Relay 1 (N.C.)
Earth pin must be connected to earth
Do not wipe grease off pins