- ページ 5
浄水器 Commodity Axis ViaAqua EF-3000 UVCのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Commodity Axis ViaAqua EF-3000 UVC 8 ページ。 Pressure pond filter
Commodity Axis ViaAqua EF-3000 UVC にも: マニュアル (16 ページ)
A) SUBMERSED
1. Place pump in the desired location. If pump is placed in a pond, raise the pump off the
bottom of the pond by a minimum of 6 inches.
2. Use Teflon tape to connect the universal elbow or coupler to the output of the pump.
3. Place the o-ring onto the barbed pipe adapter. Then, use the Teflon tape to hand tighten the
barbed pipe adapter to the universal elbow or coupler. See diagram A.
4. Connect the flexible tubing to the barbed pipe adapter. Ensure water tightness with a hose
clamp.
5. Connect to filtration or water feature.
B) FOUNTAIN HEAD
1. Place pump in the desired location.
If pump is placed in a pond, raise the
pump off the bottom of the pond by a
minimum of 6 inches.
2. Use Teflon tape to connect the
universal elbow or coupler to the output
of the pump.
3. Install the fountain head properly. See
details in diagram B.
4. The diverter valve enables water flow
to be directed to either a water feature,
Terminator
UVC Sterilizer, or a
TM
pressure pond filter.
FOUNTAIN HEAD: THREE TIER
INSTALLATION SETUP
SUBMERSED
FOUNTAIN HEAD: WATER BELL
-5-