FEED WATER SUPPLY
Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting.
A. PREFERRED INSTALLATION
1. Close the cold water supply valve under the sink.
2. Unscrew the flexible tubing from the supply valve that connects to the COLD water riser.
NOTE: If the cold water shut-off valve fails to turn off the water, the house water supply can be
turned off at the main water supply.
3. The water supply adapter can be installed at the faucet connection (A of Fig.#1) of the cold water
line or at the shut-off valve connection (B of Fig.#1) DO NOT OVERTIGHTEN
4.
Disconnect the threaded nut at the connection and thread the water supply adapter, with the flat
washer in place, onto the connection and tighten. Connect the White tubing to the water supply
adapter with the treaded nut and tighten.
5.
Thread the needle valve into the adapter tightly and turn the handle clockwise all the way in.
Open the main water supply valve and several house faucets to purge air from the system. Close
faucets when water runs smoothly.
DANGER:
Many homes are electrically grounded through the plumbing. To protect yourself from serious
injury or fatal shock, use a battery-powered hand drill only to make the hole.
DO NOT USE AN ELECTRIC DRILL.
Turn on cold water supply to the sink faucet and check for leaks
on
6 |