- ページ 6
計測機器 ATI Technologies 39-0050のPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。ATI Technologies 39-0050 19 ページ。 Digital control installation & operation

Single Feeder Connection:
(+) DC 12volts to Feeder or Solenoid/ Pin 3: 8
(-) DC 12volts to Feeder or Solenoid: 5
Double Feeder Connections:
Left Hand (+) DC 12volts to Feeder or Solenoid: 8
Left Hand (-) DC 12volts to Feeder or Solenoid: 5
Right Hand (-) DC 12volts to Feeder or Solenoid: 4
Right Hand (+) DC 12 volts to Feeder or Solenoid: 3
*
No Connection: 10
**
(+) DC 12volts from Power Supply: 7
(-) DC 12volts from Power Supply: 6
No Connection: 4
Connect to pin 8: 3
No Connection: 2
Timing Pulse from Power Supply: 1
CHECK: Serial Label displays 12 (volt)
* For abreast feeders connect
to Auto Flap Left Hand
** For abreast feeders connect
to Auto Flap Right Hand
No Connection: 10
No Connection: 9
(+) DC 12volts from Power Supply: 7
(-) DC 12volts from Power Supply: 6
No Connection: 2
Timing Pulse from Power Supply: 1
CHECK: Serial Label displays 12 (volt)
DIGITAL CONTROL
& OPERATION: 4
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
!
Link connectors
3 and 8
Single Control only