- ページ 2
除湿機 Anden A210V1のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Anden A210V1 2 ページ。
Anden A210V1 にも: 据付・取扱説明書 (16 ページ), クイック・スタート・マニュアル (4 ページ)
5A. DRAIN CONNECTIONS – A210V1
5B. DRAIN CONNECTIONS – A320V1/V3
DO NOT DOUBLE TRAP
PRIME TRAP
3/4" FEMALE PIPE
x 3/4" FNPT
3/4" MNPT x 3/4"
BARB
DRAIN TRAP
FLEXIBLE TUBE
CONSTANT DOWNWARD
SLOPE 1/8"/FT (MIN.)
PVC
RIGID PIPE
3/4" MNPT x 3/4" BARB
CABLE TIE
90-2479
anden.com
P.O. Box 1467
Madison, WI 53701-1467
800.972.3710 F: 608.257.4357
Printed in USA
©2019 Anden – A Quality brand from Research Products Corporation
10013947 B2208490A 4.19
• Mount control at canopy height.
• Do not mount in direct path of
FLEXIBLE TUBE
• Shield control from lights.
90-2479
3/4" MNPT X 3/4" SLIP FIT
PVC RIGID PIPE
CONSTANT DOWNWARD
SLOPE 1/8"/FT (MIN.)
1. Plug unit in and turn power switch to ON.
2. The on-board control screen should display OFF.
90-2479
NOTE: The first button press will only turn on the
backlight.
3. Hold the MODE button on the on-board control for
3/4" MNPT x 3/4"
FEMALE PIPE
90-2479
1. At the Model A77, press the ON button; the Model A77 will display the measured RH and ON.
2. Use the UP or DOWN button on the Model A77 to adjust the humidity setting as desired.
3. If the RH measured by the Model A77 rises above the setting, the dehumidifier will turn on. "DEHUMIDIFYING"
3/4" MNPT x 3/4"
FEMALE PIPE
DRAIN TRAP
NOTE: When using the Model A77, there is an initial 3 minute delay at power-up before the dehumidifier compressor will
turn on.
90-2479
See the Installation Instructions for troubleshooting
error codes. For additional assistance, Technical
Support is available Monday through Friday, 7:00 a.m.
to 5:00 p.m. CST, at (800) 972-3710.
Contact Technical Support before replacing the unit
or components and for additional troubleshooting.
KEEP TOP OF
LOOP BELOW THE
BOTTOMOF THE
DEHUMIDIFIER
FLEXIBLE TUBE
DRAIN TRAP
6. WIRING
dehumidifier outlet air.
A210V1
A320V1
14/3,6-15P
12/3,6-20P
7. SET-UP & SEQUENCE OF OPERATION WITH MODEL A77
3 seconds to enter the Installer Set-up Menu.
CONSTANT DOWNWARD
SLOPE 1/8"/FT (MIN.)
PVC
RIGID PIPE
SEQUENCE OF OPERATION
3/4" MNPT x 3/4" BARB
will appear on the dehumidifier control display and ON will blink on the Model A77 to show that there is a call for
dehumidification. The dehumidifier will turn off when the RH measured by the Model A77 drops 3% RH below the setting.
CABLE TIE
8. CODES
(LOCATED ON BACK OF WIRE ACCESS COVER)
3/4" MNPT X 3/4" SLIP FIT
PVC RIGID PIPE
+ - A B ODT
Remote
Sensor
CONSTANT DOWNWARD
SLOPE 1/8"/FT (MIN.)
A320V3
12/3,L7-20P
4. Press the UP or DOWN button to change to ENABLED.
5. Press MODE repeatedly until DONE shows on screen.
90-1854
6. Press ON/OFF to turn ON.
3/4" MNPT x 3/4"
FEMALE PIPE
DRAIN TRAP
90-1854
KEEP TOP OF
LOOP BELOW THE
BOTTOMOF THE
DEHUMIDIFIER
FLEXIBLE TUBE
DRAIN TRAP
ERROR CODE
FAILURE MODE
E1
Internal %RH/ Temperature Sensor Failure
E2
High Refrigeration Pressure
E3
Model 76 Remote Control Communication Loss
E4
Insufficient Capacity
E5
High Temperature Thermistor Failure
E6
Low Temperature Thermistor Failure
E7
Float Switch Open
E8
Inlet Air Temperature Out of Range
MODEL A77 CONTROL
A
B
C/-
R/+
DH
DH
90-2481
90-2480
90-1854
90-1854
3/4" MNPT x 3/4"
90-1854
CABL