スイッチ AIRTAC DPSN1-0のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。AIRTAC DPSN1-0 2 ページ。 Digital display pressure switch
DPS Series
Digital Display Pressure Switch
Precautions
Do not drop 、 knock or apply excessive impact while handling.Otherwise
could cause damage and a malfunction.
The tensile strength of the cord is 60N.Applying a greater pulling
force on it can cause a malfunction.
Do not exceed the screw-in torque of 7N m when installing piping.
Exceeding this value may cause malfunctioning of the sensor.
Do not use it with corrosive and/or flammable gases or liquids.
Please use it within rated pressure range.
Turn off the power before connecting the wires.
Don't use in an environment with spattering liquid of oil or solvent.
Separate power lines from high voltage lines,avoiding wiring in the
same conduit with these lines.
Specifications
Model
DPSN1-01、DPSN1-10、DPSP1-01、DPSP1-10
12 to 24VDC ±10%,Ripple(p-p)≤10%
Voltage
Input power
Current
45 mA or less
consumption
fluid type
Non-corrosive gas
DPSN1(P1)-01:-100kPa to 100kPa
Measurement
range
DPSN1(P1)-10:-100kPa to 1000kPa
DPSN1(P1)-01:200kPa
Pressure
Withstand
range
pressure
DPSN1(P1)-10:1500kPa
Measurement
±2% F.S. ±1 digit
error
Repeative
±0.2% F.S.
accuracy
Temperature
±3% F.S.(Base 25℃,Range 0 to 50℃ )
error
Display
Double row LCD display
Type
4-digit measurement, 3.5-digit setting
Display
Output
Color
2-color LCD (Red/Green)
Display
100ms、250ms、500ms、1000ms
period
DPSN1:Built-in two sets of NPN output
Output group
DPSP1:Built-in two sets of PNP output
NPN:Maximum applied voltage 30V/100mA,
Transistor
Retained voltage <1.5V
output
PNP:Maximum applied voltage 30V/100mA,
Switch output
Retained voltage <1.5V
2ms、20ms、50ms、100ms、250ms、500ms、
Response time
1000ms、2500ms、5000ms
DPSN1(P1)-01:0.1、0.2、0.3
Hysteresis
DPSN1(P1)-10:1、2、3
8(kPa)
...
Basic mode, Hysteresis mode, Window
Output mode
comparator mode
DPSN1(P1)-01:kPa、kgf/cm 、bar、psi、mmHg、inHg
2
Pressure Unit
DPSN1(P1)-10:MPa、kPa、kgf/cm 、bar、psi、cmHg、inHg
2
Vibration
10 to 500Hz with 10mm Amplitude in X, Y, Z directions
resistance
for 2hrs
Impact
2
Maximum 100m/s , X, Y, Z directions 3 times each
resistance
Operating
0℃ to +50℃
Temp. range
Stored
-20℃ to +65℃
Temp. range
Humidity
35% to 80% RH(No condensation)
range
30
F
G
A
A.Value up button
E.Set pressure display area
B.Setting button
F.Output 1 indicator light
C.Value Down button
G.Output 2 indicator light
D.Pressure display area
Model Description
DPS
-
Measurement range
Output type
N1:NPN
01:-100 to 100kPa
P1:PNP
10:-100 to 1000kPa
Connected mode
NULL:Plug-in
connector.
020:Length 2m
B:Rear End Cable
030:Length 3m
050:Length 5m
Piping specifications
NULL - PT 1/8 with M5 female thread
T - NPT 1/8 with 10-32UNF female thread
G - G 1/8 with M5 female thread
Connection Example
DPSN1:NPN Output
DC(+)-Brown
Load
Out1-Black
Out2-White
DC(-)-Blue
0.8(kPa)
...
DPSP1:PNP Output
DC(+)-Brown
Out2-White
Out1-Black
Load
DC(-)-Blue
28.6
Made in Taiwan
D
E
N
IP64
B
C
M5 with female
7
thread
1.Install the connector
2.Turn on the power
Lead wire
length
(Measurement mode)
Rolling
display
Press the SET button to change menu
Load
12 24V
~
Rolling
display
Rolling
display
Load
12 24V
~
Press the SET button to change menu
Hysteresis /window comparator mode
16
20
2-M3
Piping specifications:
PT 1/8 with M5 female thread
NPT 1/8 with 10-32UNF female thread
G 1/8 with M5 female thread
User Interface Instructions
(Basic mode)
(Measurement mode)
Press the SET button
for two seconds
Interface switch
Press the SET button
for two seconds
(Basic mode)
Press the value up and
Basic mode
Hysteresis mode
down button to set the
pressure value
Basic mode
Hysteresis mode
Basic mode
Output1-N.O.
Output1-N.C.
Output2-N.O.
Output2-N.O.
2ms、20ms、50ms、100ms、250ms、500ms、1000ms、2500ms、5000ms
Press the value up and
down button to set the
pressure value
Output:Red
Output:Green
No output:Green
No output:Red
Press the value up and
MPa
kPa
down button to set the
pressure value
Press the SET
button to change
menu
psi
5
4
3
2
1
1.DC(+) input (Brown)
2.OUT1 (Black)
3.OUT2 (White)
4.Retention(Orange)
5.DC(-) input (Blue)
(Advanced mode)
Press the SET button
for four seconds
Interface switch
Press the SET button
for two seconds
Interface of basic mode
Press the value up and down
button setting the value
Output1
Window comparator
mode
Output2
Window comparator
mode
Output-
Normally open
or close
Output1-N.O.
Output1-N.C.
Output2-N.C.
Output2-N.C.
Output-
Response time
Output-
Color
selection
All-time
All-time
display red
display green
2
kgf/cm
bar
Pressure unit
mmHg
cmHg