- ページ 17
冷凍庫 Electrolux A95288GAのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Electrolux A95288GA 40 ページ。
Climate class
SN
N
ST
T
Location
To ensure best performance, if the appliance is positioned below an overhanging wall unit,
the minimum distance between the top of the cabinet and the wall unit must be at least
40 mm . Ideally, however, the appliance should not be positioned below overhanging wall
units.
If the cabinet is placed in a corner and the side with the hinges facing the wall, the distance
between the wall and the cabinet must be at least 230 mm to allow the door to open
enough so that the equipment can be removed.
The ventilation space can be:
• directly above the appliance
• behind and above the top cupboard.
In this case, the space behind the top cupboard
must be at least 50 mm deep.
Electrical connection
Before plugging in, ensure that the voltage and frequency shown on the rating plate cor-
respond to your domestic power supply.
The appliance must be earthed. The power supply cable plug is provided with a contact for
this purpose. If the domestic power supply socket is not earthed, connect the appliance to
a separate earth in compliance with current regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if the above safety precautions are not ob-
served.
This appliance complies with the E.E.C. Directives.
Removing the transport support
Your appliance is equipped with transport support to secure the door during transportation.
To remove them do these steps:
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
Ambient temperature
17
Installation
50mm