7. VFS82G Series Burner Installation

When installing this series of burners, the burner is fixed to the mounting hole of the
furnace with bolts, it sholuld be noted that a gasket is required between the burner and
the furnace wall. The gasket may be ceramic fiber or glass fiber. When the burner is
installed, the burner can be rotated according to the site condition. After burner is installed,
make the related components wired. The combustion air inlet pipeline of the combustor
could be moved in the normal direction. It could be moved and adjusted when the flame
signal is not good or the occurrence of a ringing phenomenon occurs in the ignition area.
VFS82 series of burner installation dimensions as Fig. 8.
Different types of VFS82 burner dimensions shown as Table 2.
VFS82G
A(mm)
30
927
50
1080
65
1207
95
1397
120
1524
160
1702
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – VFS82 Burner Operation Manual
Fig. 8 VFS82G Serises Burener Installtion Diagram
Table 2 VFS82G Series Burner Installation Dimension
B(mm)
C(mm)
12
772
12
899
12
1000
16
1153
16
1280
24
1407
D(mm)
E
229
2.5'
305
3'
381
3'
457
3
533
DN100
622
DN100
8
F(mm)
G(mm)
991
641
1143
838
1270
984
1473
1203
1600
1394
1778
1557